OSHA SearchOSHA records by employer

Onsite Development, LLC: OSHA inspections and violations

Charlotte, North Carolina · Water and Sewer Line and Related Structures Construction · NAICS 237110

7inspections
18citation items
$133,675current penalties
Aug 15, 2022last inspection

OSHA has inspected Onsite Development, LLC 7 times in North Carolina since 2006.

The latest one began on Aug 15, 2022 after a complaint, in Charlotte.

Those inspections ended with 18 citation items: 14 serious, 1 willful, 2 repeat and 1 other-than-serious.

Penalties were first proposed at $150,475 and now stand at $133,675, 11% lower after settlements or reviews.

Trench protection comes up most often in these citations: 8 items under 1926.652.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Onsite Development, LLC averages $65,600 (2 cited inspections).

Onsite Development, LLC: OSHA citation items per year, 2006 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Onsite Development, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346153463 OPENED AUG 15, 2022Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Jan 20, 2023

4229 Carrowmore Place, Charlotte, NC 28208 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345848733 OPENED MAR 18, 2022Closed

Referral · Partial · Health · 3 employees at the site · Closed Nov 12, 2024

2803 Saddleback Court, Charlotte, NC 28210 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$70,000$70,000Sep 14, 2022Final
Citation 2, item 1
29 CFR 1926.651(k)(1) · Excavations
Serious$8,400$8,400Sep 14, 2022Final
Citation 3, item 1
29 CFR 1926.652(g)(1)(ii) · Trench protection
Serious$4,200$4,200Sep 14, 2022Final

Inspection 343659462 OPENED DEC 12, 2018Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jun 16, 2020

3615 And 3609 Barringer Drive, Charlotte, NC 28217 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Willful$42,000$31,500Apr 24, 2019Final
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,800$1,350Apr 24, 2019Final
Citation 2, item 2
29 CFR 1926.251(b)(1) · Rigging equipment for material handling
Serious$4,200$3,150Apr 24, 2019Final
Citation 2, item 3
29 CFR 1926.251(b)(6)(i) · Rigging equipment for material handling
Serious$4,200$3,150Apr 24, 2019Final
Citation 2, item 4
29 CFR 1926.651(c)(2) · Excavations
Serious$4,200$3,150Apr 24, 2019Final
Citation 2, item 5
29 CFR 1926.651(j)(2) · Excavations
Serious$4,200$3,150Apr 24, 2019Final
Citation 2, item 6
29 CFR 1926.651(k)(1) · Excavations
Serious$4,200$3,150Apr 24, 2019Final

Inspection 313966954 OPENED OCT 22, 2009Closed

Planned · Partial · Safety · 17 employees at the site · Closed Mar 4, 2010

Near 400 Queens Rd., Charlotte, NC 28207 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.652(a)(1) · Trench protection
Repeat$1,800$1,200Nov 6, 2009Closed
Citation 1, item 1b
29 CFR 1926.652(c)(1) · Trench protection
Repeat$0$0Nov 6, 2009Closed
Citation 2, item 1
29 CFR 1926.651(k)(1) · Excavations
Serious$600$600Nov 6, 2009Closed
Citation 3, item 1
29 CFR 1926.652(c)(2)(iii) · Trench protection
Other-than-serious$0$0Nov 6, 2009Closed

Inspection 312721012 OPENED OCT 1, 2008Closed

Planned · Partial · Safety · 14 employees at the site · Closed Nov 12, 2008

Near 208 Hartford Ave., Charlotte, NC 28209 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.652(a)(1) · Trench protection
Serious$175$175Oct 14, 2008Closed
Citation 1, item 1b
29 CFR 1926.652(c)(1) · Trench protection
Serious$0$0Oct 14, 2008Closed
Citation 1, item 1c
29 CFR 1926.651(c)(2) · Excavations
Serious$0$0Oct 14, 2008Closed

Inspection 312242076 OPENED APR 22, 2008Closed

Planned · Partial · Safety · 16 employees at the site · Closed Apr 25, 2008

Hartford And Beltran, Charlotte, NC 28209 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309809283 OPENED JUL 14, 2006Closed

Referral · Partial · Health · 9 employees at the site · Closed Aug 31, 2006

1449 Pinetree Drive, Charlotte, NC 28270 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(b)(3) · Excavations
Serious$500$500Jul 21, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.251 · Rigging equipment for material handling

29 CFR 1926.251(b)(1)

(b) Alloy steel chains. (1) Welded alloy steel chain slings shall have permanently affixed durable identification stating size, grade, rated capacity, and sling manufacturer.

29 CFR 1926.251(b)(6)(i)

(6) Inspections. (i) In addition to the inspection required by other paragraphs of this section, a thorough periodic inspection of alloy steel chain slings in use shall be made on a regular basis, to be determined on the basis of (A) frequency of sling use; (B) severity of service conditions; (C) nature of lifts being made; and (D) experience gained on the service life of slings used in similar circumstances. Such inspections shall in no event be at intervals greater than once every 12 months.

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in North Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.