OSHA SearchOSHA records by employer

Onyx Blasting and Coating, LLC: OSHA inspections and violations

Marshfield, Massachusetts · Remediation Services · NAICS 562910

2inspections
10citation items
$12,000current penalties
May 25, 2021last inspection

OSHA has inspected Onyx Blasting and Coating, LLC 2 times in Massachusetts since 2021.

The latest one began on May 25, 2021 after a complaint, in Marshfield.

Those inspections ended with 10 citation items: 10 serious.

Penalties were first proposed at $31,656 and now stand at $12,000, 62% lower after settlements or reviews.

Lead in construction comes up most often in these citations: 2 items under 1926.62.

How that compares: the median penalty per cited inspection for staffing, cleaning and waste services employers since 2015 is $2,217, and Onyx Blasting and Coating, LLC averages $6,000 (2 cited inspections).

Onyx Blasting and Coating, LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

260employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Onyx Blasting and Coating, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345325773 OPENED MAY 25, 2021Closed

Complaint · Partial · Health · 3 employees at the site · Closed Jun 12, 2024

1129 Forest Street, Marshfield, MA 02050 · Remediation Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.51(f)(1) · Sanitation
Serious$1,492$750Sep 16, 2021Final
Citation 1, item 2a
29 CFR 1926.62(d)(1)(i) · Lead in construction
Serious$1,492$750Sep 16, 2021Final
Citation 1, item 2b
29 CFR 1926.62(d)(2)(v)(e) · Lead in construction
Serious$0$0Sep 16, 2021Final

Inspection 345327076 OPENED MAY 25, 2021Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Jun 12, 2024

1129 Forest Street, Marshfield, MA 02050 · Remediation Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Serious$4,096$2,048Sep 3, 2021Final
Citation 1, item 2a
29 CFR 1926.451(d)(3)(i) · Scaffolds, general requirements
Serious$4,096$3,202Sep 3, 2021Final
Citation 1, item 2b
29 CFR 1926.451(g)(1)(ii) · Scaffolds, general requirements
Serious$4,096$0Sep 3, 2021Final
Citation 1, item 2c
29 CFR 1926.454(a) · Scaffold training
Serious$4,096$0Sep 3, 2021Final
Citation 1, item 3a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,096$3,202Sep 3, 2021Final
Citation 1, item 3b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$4,096$0Sep 3, 2021Final
Citation 1, item 4
29 CFR 1926.1053(a)(19)(iii) · Ladders in construction
Serious$4,096$2,048Sep 3, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(ii)

(ii) Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(a)(19)(iii)

(iii) A cage or well, and multiple ladder sections, each ladder section not to exceed 50 feet (15.2 m) in length. Ladder sections shall be offset from adjacent sections, and landing platforms shall be provided at maximum intervals of 50 feet (15.2 m).

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(d)(3)(i)

(i) Before the scaffold is used, direct connections shall be evaluated by a competent person who shall confirm, based on the evaluation, that the supporting surfaces are capable of supporting the loads to be imposed. In addition, masons' multi-point adjustable suspension scaffold connections shall be designed by an engineer experienced in such scaffold design.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.51 · Sanitation

29 CFR 1926.62 · Lead in construction

Other remediation services employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.