OSHA SearchOSHA records by employer

Oregon Water Services Inc: OSHA inspections and violations

Eugene, Oregon · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

2inspections
10citation items
$2,520current penalties
Mar 6, 2023last inspection

Since 2020, OSHA inspectors have visited Oregon Water Services Inc in Oregon 2 times.

The most recent inspection opened on Mar 6, 2023 as a planned inspection, in Eugene.

In all, OSHA issued 10 citation items: 3 serious and 7 other-than-serious.

The penalties, $2,520 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Oregon Water Services Inc averages $1,260 across 2 cited inspections.

Oregon Water Services Inc: OSHA citation items per year, 2020 to 2023
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

391employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Oregon Water Services Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346571011 OPENED MAR 6, 2023Closed

Planned · Complete · Safety · 12 employees at the site · Closed Oct 10, 2023

30086 Federal Ln, Eugene, OR 97402 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-002-0041(4)(C)-1
Other-than-serious$0$0Apr 25, 2023Final
Citation 1, item 2
29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks
Serious$120$120Apr 25, 2023Final
Citation 2, item 3
29 CFR OAR 437-002-0378(4)(A)
Other-than-serious$0$0Apr 25, 2023Final
Citation 2, item 4
29 CFR 1910.305(c)(4) · Electrical wiring methods
Other-than-serious$0$0Apr 25, 2023Final
Citation 2, item 5
29 CFR OAR 437-002-0022(4)(F)
Other-than-serious$0$0Apr 25, 2023Final
Citation 2, item 6
29 CFR OAR 437-002-0187(1)-7
Other-than-serious$0$0Apr 25, 2023Final
Citation 2, item 7
29 CFR OAR 437-002-0042(1)(B)-1
Other-than-serious$0$0Apr 25, 2023Final
Citation 2, item 8
29 CFR OAR 437-002-2102(1)(E)(A)(II)
Other-than-serious$0$0Apr 25, 2023Final

Inspection 345142889 OPENED AUG 28, 2020Closed

Accident · Partial · Safety · 12 employees at the site · Closed Aug 2, 2021

85802 Loop Ln, Eugene, OR 97405 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Aug 27, 2020: Employee incurs burns to hand and foot after electrical shoc

At 10:30 a.m. on August 27, 2020, while using a boom truck to pull a pump and pipe from a well, the boom made contact with a 12,000-volt overhead electrical line. The employee was shocked by the electrical current and sustained burns on his left foot and left hand. The employee was transported to the hospital for treatment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.333(c)(3)(iii)(a) · Working near live electrical parts
Serious$2,400$2,400Feb 17, 2021Final
Citation 1, item 1b
29 CFR OAR 437-001-0760(1)(A)-1
Serious$0$0Feb 17, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(a)(6)

(6) The user shall see that all nameplates and markings are in place and are maintained in a legible condition.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(c)(4)

(4) Faceplates for flush-mounted snap switches. Snap switches mounted in boxes shall have faceplates installed so as to completely cover the opening and seat against the finished surface.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(c)(3)(iii)(a)

(iii) Vehicular and mechanical equipment. (A) Any vehicle or mechanical equipment capable of having parts of its structure elevated near energized overhead lines shall be operated so that a clearance of 10 ft. (305 cm) is maintained. If the voltage is higher than 50kV, the clearance shall be increased 4 in. (10 cm) for every 10kV over that voltage. However, under any of the following conditions, the clearance may be reduced:

Other plumbing, heating, and air-conditioning contractors employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.