OSHA SearchOSHA records by employer

Orlando Cisnado: OSHA inspections and violations

Katy, Texas · All Other Specialty Trade Contractors · NAICS 238990

1inspections
4citation items
$6,800current penalties
Sep 2, 2015last inspection

OSHA inspectors have visited Orlando Cisnado in Texas one time.

It opened on Sep 2, 2015 as a planned inspection, in Katy.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $6,800 in total, stand where OSHA first set them.

The rule cited most here is 1926.452 (rules for each type of scaffold), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Orlando Cisnado averages $6,800 across 1 cited inspection.

Orlando Cisnado: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Orlando Cisnado and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340897198 OPENED SEP 2, 2015Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jul 15, 2019

24600 Kingsland Blvd, Katy, TX 77494 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,000$2,000Sep 24, 2015Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,800$2,800Sep 24, 2015Final
Citation 1, item 3a
29 CFR 1926.452(j)(1) · Rules for each type of scaffold
Serious$2,000$2,000Sep 24, 2015Final
Citation 1, item 3b
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Sep 24, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(1)

(j) Pump jack scaffolds. (1) Pump jack brackets, braces, and accessories shall be fabricated from metal plates and angles. Each pump jack bracket shall have two positive gripping mechanisms to prevent any failure or slippage.

Other all other specialty trade contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.