OSHA SearchOSHA records by employer

Orochem Technologies Inc.: OSHA inspections and violations

Westmont, Illinois · Analytical Laboratory Instrument Manufacturing · NAICS 334516

2inspections
6citation items
$25,210current penalties
Dec 20, 2018last inspection

OSHA has inspected Orochem Technologies Inc. 2 times in Illinois since 2002.

The latest one began on Dec 20, 2018 on a referral, in Naperville.

Those inspections ended with 6 citation items: 6 serious.

Penalties were first proposed at $37,428 and now stand at $25,210, 33% lower after settlements or reviews.

Personal protective equipment, general requirements comes up most often in these citations: 2 items under 1910.132.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Orochem Technologies Inc. averages $25,000 (1 cited inspection).

Orochem Technologies Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Orochem Technologies Inc.: OSHA citation items per year, 2002 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Orochem Technologies Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343675625 OPENED DEC 20, 2018Closed

Referral · Partial · Health · 35 employees at the site · Closed Jul 29, 2019

340 Shuman Blvd, Naperville, IL 60563 · Analytical Laboratory Instrument Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Dec 14, 2018: Employee sustains second degree burns to hands and back duri

At 8:00 a.m. on December 14, 2018, an employee was transferring toluene from a 55 gallon drum into another using a hand pump when a static electricity sparked and the toluene flared up. The employee sustained second degree burns to his hands and back before being hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$9,282$6,250Apr 3, 2019Final
Citation 1, item 1b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Apr 3, 2019Final
Citation 1, item 2
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$9,282$6,250Apr 3, 2019Final
Citation 1, item 3
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$9,282$6,250Apr 3, 2019Final
Citation 1, item 4
29 CFR 1910.138(a) · Gloves and hand protection
Serious$9,282$6,250Apr 3, 2019Final

Inspection 305157810 OPENED DEC 19, 2002Closed

Complaint · Partial · Health · 12 employees at the site · Closed Jan 30, 2003

762 Burr Oak Dr., Westmont, IL 60559 · Analytical Laboratory Instrument Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h) · Hazard communication
Serious$300$210Jan 13, 2003Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Naperville site logged 0 recordable injuries or illnesses among about 36 workers: 0.0 per 100 full-time workers, against a median of 0.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Orochem Technologies Inc
Naperville · 2017
36 000.00.0

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Dec 14, 2018, Naperville: Hospitalization · second degree heat (thermal) burns · multiple body parts, n.e.c.

An employee was transferring toluene solvent from one drum to another using a hand pump. A discharge of static electricity ignited the toluene which then splashed onto the employee's clothing. The employee was hospitalized with second degree burns to his left hand, back, and other parts of the body.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.138 · Gloves and hand protection

Other analytical laboratory instrument manufacturing employers in Illinois

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.