OSHA SearchOSHA records by employer

P 2 Contracting LLC: OSHA inspections and violations

Pittsburgh, Pennsylvania · Commercial and Institutional Building Construction · NAICS 236220

2inspections
16citation items
$10,640current penalties
Jul 11, 2018last inspection

OSHA has inspected P 2 Contracting LLC 2 times in Pennsylvania since 2015.

The latest one began on Jul 11, 2018 as a planned inspection, in Pittsburgh.

Those inspections ended with 16 citation items: 14 serious and 2 other-than-serious.

Penalties were first proposed at $19,127 and now stand at $10,640, 44% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 5 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and P 2 Contracting LLC averages $5,320 (2 cited inspections).

P 2 Contracting LLC: OSHA citation items per year, 2015 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

297employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch P 2 Contracting LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343296067 OPENED JUL 11, 2018Closed

Planned · Partial · Safety · 30 employees at the site · Closed Sep 11, 2018

955 Liberty Avenue, Pittsburgh, PA 15222 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$4,268$2,300Aug 9, 2018Final
Citation 1, item 1b
29 CFR 1926.405(a)(2)(ii)(b) · Job-site wiring
Serious$0$0Aug 9, 2018Final
Citation 1, item 1c
29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring
Serious$0$0Aug 9, 2018Final
Citation 1, item 1d
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$0$0Aug 9, 2018Final
Citation 1, item 1e
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$0$0Aug 9, 2018Final
Citation 1, item 1f
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Aug 9, 2018Final
Citation 1, item 2a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$5,691$3,100Aug 9, 2018Final
Citation 1, item 2b
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$0$0Aug 9, 2018Final
Citation 1, item 2c
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$0$0Aug 9, 2018Final
Citation 1, item 2d
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Aug 9, 2018Final
Citation 1, item 3a
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$4,268$2,300Aug 9, 2018Final
Citation 1, item 3b
29 CFR 1926.1052(c)(8) · Stairways in construction
Serious$0$0Aug 9, 2018Final
Citation 2, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$0$0Aug 9, 2018Final

Inspection 340452846 OPENED MAR 10, 2015Closed

Unprogrammed other · Complete · Safety · 26 employees at the site · Closed Apr 15, 2015

7401 Mcknight Road, Pittsburgh, PA 15237 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$4,900$2,940Mar 27, 2015Final
Citation 1, item 1b
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$0$0Mar 27, 2015Final
Citation 2, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$0$0Mar 27, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.1052(c)(8)

(8) Stairrail systems and handrails shall be so surfaced as to prevent injury to employees from punctures or lacerations, and to prevent snagging of clothing.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other commercial and institutional building construction employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.