Inspection 349004358 OPENED JUN 17, 2026Closed
216 East Valley View Street, Derby, KS 67037 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2000, OSHA inspectors have visited Par Electrical Contractors, LLC in Kansas 8 times.
The most recent inspection opened on Jun 17, 2026 on a referral, in Derby.
In all, OSHA issued 5 citation items: 1 serious, 1 repeat and 3 other-than-serious.
The proposed penalties came to $89,000; today they stand at $73,000, 18% less.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Par Electrical Contractors, LLC averages $5,000 across 1 cited inspection.
2 inspections on this page followed a fatal incident.
It reported 2 severe injuries to OSHA since 2015.
Kansas · latest 90 days of OSHA records
43employers cited
Get notified the morning OSHA posts each new citation in Kansas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Kansas
Checking a subcontractor, a client or your own company? Watch Par Electrical Contractors, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company216 East Valley View Street, Derby, KS 67037 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7560 Norwood Street, Prairie Village, KS 66208 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
12721 Pawnee Ln., Leawood, KS 66209 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5115 Belinder Rd., Westwood, KS 66205 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.269(l)(6)(iii) · Electric power generation, transmission, and distribution |
Other-than-serious | $7,000 | $5,000 | Apr 12, 2016 | Final |
1 Mile East Of Colby, Ks On Hwy 24, Colby, KS 67701 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
Incident on Aug 6, 2008 (fatal): One employee is killed, two are burned in electric shock
At approximately 08:45 a.m. on August 6, 2008, Employees #1, #2, #3 and a cowork er, a four-member electrical line crew, was installing new poles at the job site . Employees #1 and #2 were pushing and guiding a 50-ft tall pole to place in a 7 -ft deep hole that was just dug, and which was adjacent to existing electrical p ole. As the pole was being moved, it came in contact with the unprotected 115,00 0 kvw energized transmission lines. Employee #1 was burned in his shoulder and d ied at the scene from the electric shock. Employee #2 was burned in his abdomen and Employee #3 was severely burned in his hands. Employees #2 and #3 were trans ported by Air Ambulance to a hospital in Wichita, Kansas. They were hospitalized .
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.955(a)(6)(i) · Portable ladders and platforms |
Other-than-serious | $7,000 | $7,000 | Jan 27, 2009 | Final |
| Citation 2, item 1 29 CFR 1926.953(d) · Enclosed spaces |
Repeat | $70,000 | $56,000 | Jan 26, 2009 | Final |
E. 2150 Rd. & Yancy Rd., La Cygne, KS 66040 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Mar 27, 2006 (fatal): Employee is killed in fall from power lines
On March 27, 2006, Employee #1, an employee of Par Electrical Contractors, Inc., was removing connectors from overhead power lines. Employee #1 was in a spacer cart that was set on power lines when the hook used to lift the spacer cart beca me entangled with the power line. During an attempt to remove the hook from the power line, the ball fell below the line, the hook turned so that its mouth was toward the ground, and the nylon mesh slings fell through the hook. The cart, wi th Employee #1, fell approximately 105 ft. Employee #1 was killed.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.20(b)(1) · Construction safety programs |
Serious | $5,000 | $5,000 | Jul 19, 2006 | Final |
| Citation 1, item 1b 29 CFR 1926.21(b)(2) · Construction safety training |
Other-than-serious | $0 | $0 | Jul 19, 2006 | Final |
Kellogg & Governor, Eastborough, KS 67207 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
117th & Renner, Olathe, KS 66061 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
Jun 28, 2025, Prairie Village: Hospitalization · electrocution, electric shock · body systems
Three employees were responding to a power outage caused by a recent storm. While climbing a utility pole, an employee contacted an electrical component with his left hand, thumb, and index finger, resulting in an electrical shock and probable exposure to an arc flash. The injured employee lost consciousness and was found hanging upside down in his rope harness, requiring resuscitation and…
Aug 18, 2022, Leawood: Hospitalization · electrical burns, unspecified · elbow(s) and arms(s)
An employee was working with a trenching crew to run conduit to a pad-mounted transformer. The employee made contact with a component of the transformer and was exposed to an arc flash. The employee was hospitalized with burns to the right elbow and forearm.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.269(l)(6)(iii)
(iii) When lines or equipment are connected to or disconnected from energized circuits, an employee shall keep loose conductors away from exposed energized parts.
29 CFR 1926.20(b)(1)
(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.
29 CFR 1926.21(b)(2)
(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.
Alert subscribers get notified of each newly cited employer in Kansas the morning it is posted. See the alert plans.