Inspection 342644093 OPENED SEP 7, 2017Closed
1930 Kumry Road, Quakertown, PA 18951 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Quakertown, Pennsylvania · All Other Miscellaneous Chemical Product and Preparation Manufacturing · NAICS 325998
Since 1995, OSHA inspectors have visited Particle Size Technology, Inc. in Pennsylvania 4 times.
The most recent inspection opened on Sep 7, 2017 to follow up on an earlier case, in Quakertown.
In all, OSHA issued 11 citation items: 8 serious and 3 other-than-serious.
The proposed penalties came to $7,600; today they stand at $5,320, 30% less.
The rule cited most here is 1910.134 (respiratory protection), 4 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Particle Size Technology, Inc. averages $2,660 across 2 cited inspections.
Particle Size Technology, Inc. also files yearly injury logs with OSHA, summarized below.
Pennsylvania · latest 90 days of OSHA records
285employers cited
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Particle Size Technology, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company1930 Kumry Road, Quakertown, PA 18951 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1930 Kumry Road, Quakertown, PA 18951 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3a 29 CFR 1910.95(d)(1) · Noise |
Serious | $2,000 | $2,800 | May 5, 2016 | Final |
| Citation 1, item 3b 29 CFR 1910.95(g)(1) · Noise |
Serious | $0 | $0 | May 5, 2016 | Final |
| Citation 1, item 3c 29 CFR 1910.95(k)(1) · Noise |
Serious | $2,000 | $0 | May 5, 2016 | Final |
1930 Kumry Road, Quakertown, PA 18951 · All Other Miscellaneous Chemical Product and Preparation Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $1,600 | $1,120 | Mar 15, 2016 | Final |
| Citation 1, item 1b 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Serious | $0 | $0 | Mar 15, 2016 | Final |
| Citation 1, item 1c 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Mar 15, 2016 | Final |
| Citation 1, item 1d 29 CFR 1910.134(k) · Respiratory protection |
Serious | $0 | $0 | Mar 15, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts |
Serious | $2,000 | $1,400 | Mar 15, 2016 | Final |
| Citation 2, item 1 29 CFR 1904.32(a)(4) · Yearly injury summary |
Other-than-serious | $0 | $0 | Mar 15, 2016 | Final |
| Citation 2, item 2a 29 CFR 1910.303(e)(1)(i) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 15, 2016 | Final |
| Citation 2, item 2b 29 CFR 1910.303(e)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 15, 2016 | Final |
5189 Stump Road, Plumsteadville, PA 18949 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2023, the Quakertown site logged 1 recordable injury or illness among about 24 workers: 4.1 per 100 full-time workers, against a median of 0.7 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Particle Size Technology, Inc Quakertown · 2023 | 24 | 1 | 0 | 4.1 | 0.7 |
Included with any plan: 4 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(1)
(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.
29 CFR 1910.134(c)(2)(i)
(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.