OSHA SearchOSHA records by employer

Patterson Products Inc.: OSHA inspections and violations

Noble, Illinois · Plastics Plumbing Fixture Manufacturing · NAICS 326191

2inspections
11citation items
$16,609current penalties
May 23, 2023last inspection

OSHA has inspected Patterson Products Inc. 2 times in Illinois since 2023.

The latest one began on May 23, 2023 after a complaint, in Noble.

Those inspections ended with 11 citation items: 10 serious and 1 other-than-serious.

Penalties were first proposed at $30,360 and now stand at $16,609, 45% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 4 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Patterson Products Inc. averages $8,304 (2 cited inspections).

Patterson Products Inc.: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

423employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Patterson Products Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346726532 OPENED MAY 23, 2023Closed

Complaint · Partial · Health · 15 employees at the site · Closed May 27, 2025

580 E. Antioch Lane, Noble, IL 62868 · Plastics Plumbing Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$3,572$2,143Aug 15, 2023Final
Citation 1, item 2
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$4,465$2,679Aug 15, 2023Final
Citation 1, item 3
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$2,678$0Aug 15, 2023Final
Citation 1, item 4a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$6,250$3,750Aug 15, 2023Final
Citation 1, item 4b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Aug 15, 2023Final
Citation 1, item 4c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Aug 15, 2023Final
Citation 1, item 4e
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Aug 15, 2023Final
Citation 1, item 5a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$4,465$2,679Aug 15, 2023Final
Citation 1, item 5b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Aug 15, 2023Final

Inspection 346571839 OPENED MAR 16, 2023Closed

Complaint · Partial · Safety · 15 employees at the site · Closed May 27, 2025

580 E. Antioch Lane, Noble, IL 62868 · Plastics Plumbing Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(2) · Exit routes
Serious$4,465$2,679Aug 18, 2023Final
Citation 1, item 2
29 CFR 1910.38(b) · Emergency action plans
Serious$4,465$2,679Aug 18, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(g)(7)

(7) “No Smoking” signs. “No smoking” signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

Other plastics plumbing fixture manufacturing employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.