OSHA SearchOSHA records by employer

Paul Saunders Roofing Co. Inc.: OSHA inspections and violations

Richmond, Virginia · Roofing Contractors · NAICS 238160

6inspections
18citation items
$35,860current penalties
Oct 24, 2025last inspection

Since 2002, OSHA inspectors have visited Paul Saunders Roofing Co. Inc. in Virginia 6 times.

The most recent inspection opened on Oct 24, 2025, in Richmond.

In all, OSHA issued 18 citation items: 12 serious, 4 repeat and 2 other-than-serious.

The proposed penalties came to $50,885; today they stand at $35,860, 30% less.

The rule cited most here is 1926.501 (fall protection in construction), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Paul Saunders Roofing Co. Inc. averages $10,803 across 3 cited inspections.

Paul Saunders Roofing Co. Inc. also files yearly injury logs with OSHA, summarized below.

Paul Saunders Roofing Co. Inc.: OSHA citation items per year, 2002 to 2025
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

22 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Paul Saunders Roofing Co. Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348566852 OPENED OCT 24, 2025Closed

Programmed other · Partial · Safety · 10 employees at the site · Closed Nov 18, 2025

700 E. 4th Street, Richmond, VA 23224 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347464091 OPENED MAY 7, 2024Open

Referral · Partial · Safety · 2 employees at the site · Open

2001 Stuart Avenue, Richmond, VA 23220 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,980$1,287Aug 16, 2024Final
Citation 1, item 1b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Aug 16, 2024Final
Citation 1, item 1c
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$0$0Aug 16, 2024Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$19,495$11,697Aug 16, 2024Final
Citation 2, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Repeat$14,850$9,652Aug 16, 2024Final

Inspection 345891741 OPENED APR 12, 2022Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Aug 4, 2022

109 N Davis Avenue, Richmond, VA 23220 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$5,190$5,190Jun 17, 2022Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Repeat$3,565$3,565Jun 17, 2022Final

Inspection 345242952 OPENED APR 9, 2021Closed

Planned · Partial · Safety · 23 employees at the site · Closed Jun 29, 2021

3407 Hawthorne Ave., Richmond, VA 23222 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$855$598Apr 21, 2021Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$600$420Apr 21, 2021Final
Citation 2, item 1
29 CFR 1926.50(c) · Medical services and first aid
Other-than-serious$0$0Apr 21, 2021Final

Inspection 316065770 OPENED SEP 29, 2011Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Nov 28, 2011

Old Dominion Hall, Williamsburg, VA 23185 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,100$2,100Nov 17, 2011Closed

Inspection 305645087 OPENED OCT 4, 2002Closed

Planned · Complete · Safety · 3 employees at the site · Closed Dec 3, 2002

2718 Monument Avenue, Richmond, VA 23220 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$1,500$900Oct 9, 2002Closed
Citation 1, item 1b
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$0$0Oct 9, 2002Closed
Citation 1, item 1c
29 CFR 1926.503(a)(2) · Fall protection training in construction
Serious$0$0Oct 9, 2002Closed
Citation 1, item 2
29 CFR 1926.50(c) · Medical services and first aid
Serious$375$225Oct 9, 2002Closed
Citation 1, item 3a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$375$225Oct 9, 2002Closed
Citation 1, item 3b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Oct 9, 2002Closed
Citation 2, item 1
29 CFR 1926.50(d)(2) · Medical services and first aid
Other-than-serious$0$0Oct 9, 2002Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Richmond site logged 0 recordable injuries or illnesses among about 18 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Paul Saunders Roofing Co Inc
Richmond · 2025
18 000.02.8

Included with any plan: 4 more yearly logs from these sites, back to 2021, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.