OSHA inspectors have visited Pentair Flow Technologies, LLC* in Illinois one time.
It opened on Feb 7, 2017 on a referral, in North Aurora.
In all, OSHA issued 6 citation items: 6 serious.
The proposed penalties came to $52,512; today they stand at $30,000, 43% less.
The rule cited most here is 1910.147 (lockout/tagout), 2 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Pentair Flow Technologies, LLC* averages $30,000 across 1 cited inspection.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Illinois · latest 90 days of OSHA records
421employers cited
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
Checking a subcontractor, a client or your own company? Watch Pentair Flow Technologies, LLC* and get notified the morning OSHA posts a new citation for it.
OSHA records show Pentair Flow Technologies, LLC* at 3 sites in 3 states. Together they've had 5 inspections and $66,979 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 3 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Incident on Jan 27, 2017: Employee's arm is caught in a milling machine spindle and l
At 2:15 p.m. on January 27, 2017, an employee was operating a horizontal milling machine. The employee stopped the operation to inspect the part. He opened the door and reached inside the machine. The spindle was spinning and the employee's sleeve got caught in the spindle which severely lacerated the his right arm. his right arm.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Jan 27, 2017, North Aurora: Hospitalization · cuts, lacerations · arm(s), unspecified
An employee was operating a horizontal milling machine when his right arm was caught by the spindle blade and severely lacerated. The employee was hospitalized.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
29 CFR 1910.147(d)
(d) Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:
(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.