OSHA SearchOSHA records by employer

Pepper Lawson Waterworks: OSHA inspections and violations

Hempstead, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

3inspections
7citation items
$11,200current penalties
May 20, 2015last inspection

OSHA has inspected Pepper Lawson Waterworks 3 times in Texas since 2012.

The latest one began on May 20, 2015, in Laredo.

Those inspections ended with 7 citation items: 3 serious and 4 other-than-serious.

Penalties were first proposed at $21,530 and now stand at $11,200, 48% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Pepper Lawson Waterworks averages $7,150 (1 cited inspection).

Pepper Lawson Waterworks: OSHA citation items per year, 2012 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Pepper Lawson Waterworks and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340646017 OPENED MAY 20, 2015Closed

Unprogrammed other · Complete · Safety · 2,000 employees at the site · Closed Sep 21, 2015

309 River Front St, Laredo, TX 78046 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(3) · Construction safety training
Other-than-serious$3,000$2,150Sep 1, 2015Final
Citation 1, item 2
29 CFR 1926.51(f)(1) · Sanitation
Other-than-serious$4,000$1,000Sep 1, 2015Final
Citation 1, item 3
29 CFR 1926.95(a) · Criteria for personal protective equipment
Other-than-serious$4,000$4,000Sep 1, 2015Final

Inspection 338977671 OPENED MAR 26, 2013Closed

Referral · Complete · Safety · 14 employees at the site · Closed May 29, 2013

17520 House Hahl Road, Cypress, TX 77433 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$2,430$0May 8, 2013Final
Citation 1, item 2a
29 CFR 1926.501(b)(5) · Fall protection in construction
Serious$5,670$2,835May 8, 2013Final
Citation 1, item 2b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0May 8, 2013Final
Citation 1, item 3
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Serious$2,430$1,215May 8, 2013Final

Inspection 337245013 OPENED NOV 5, 2012Closed

Planned · Complete · Safety · 40 employees at the site · Closed Nov 5, 2012

23rd And Hamilton Road, Hempstead, TX 77445 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(5)(i)

(5)(i) Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(3)

(3) Employees required to handle or use poisons, caustics, and other harmful substances shall be instructed regarding the safe handling and use, and be made aware of the potential hazards, personal hygiene, and personal protective measures required.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.51 · Sanitation

29 CFR 1926.95 · Criteria for personal protective equipment

Other water and sewer line and related structures construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.