OSHA SearchOSHA records by employer

Piast Auto Rebuilders, Inc.: OSHA inspections and violations

Chicago, Illinois · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

1inspections
11citation items
$3,920current penalties
May 18, 2015last inspection

OSHA has inspected Piast Auto Rebuilders, Inc. once in Illinois.

The inspection began on May 18, 2015 on a referral, in Chicago.

That inspection ended with 11 citation items: 9 serious and 2 other-than-serious.

Penalties were first proposed at $5,600 and now stand at $3,920, 30% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 4 items under 1910.134.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Piast Auto Rebuilders, Inc. averages $3,920 (1 cited inspection).

Piast Auto Rebuilders, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

428employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Piast Auto Rebuilders, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340639848 OPENED MAY 18, 2015Closed

Referral · Partial · Safety · 9 employees at the site · Closed Jan 21, 2020

805 North Kilpatrick Avenue, Chicago, IL 60651 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$1,200$840Oct 16, 2015Final
Citation 1, item 1b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Oct 16, 2015Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,200$840Oct 16, 2015Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Oct 16, 2015Final
Citation 1, item 2c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Oct 16, 2015Final
Citation 1, item 2d
29 CFR 1910.134(k)(3) · Respiratory protection
Serious$0$0Oct 16, 2015Final
Citation 1, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$2,000$1,400Oct 16, 2015Final
Citation 1, item 4a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,200$840Oct 16, 2015Final
Citation 1, item 4b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Oct 16, 2015Final
Citation 2, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 16, 2015Final
Citation 2, item 2
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 16, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.305 · Electrical wiring methods

Other automotive body, paint, and interior repair and maintenance employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.