Inspection 345098891 OPENED NOV 9, 2020Closed
3125 22nd St Se, Salem, OR 97302 · Laminated Plastics Plate, Sheet (except Packaging), and Shape Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Nov 3, 2020: Five fingers on temporary employee's hand are amputated by s
At 12:45 a.m. on November 3, 2020, an employee was working for a temporary staffing agency. He had been sent to work at a firm that manufactured laminated plastic sheets, plates, and other shapes. The employee was working as a contract laborer. He was operating an OMGA model number RN 350 FM US radial arm saw. He was cutting a plastic part to size with the radial arm saw while inappropriately wearing an oversized "hot glove." The glove was caught by the saw, and his left hand was pulled into the saw. All five fingers on his left hand were amputated. The employee was hospitalized. The saw was equipped with the manufacturer's point of operation guard, but the employer's procedure in place at the time of the incident exposed the hands of the operator to the point of operation, rendering the manufacturer's guard ineffective. There were two UPAs associated with this incident. The UPA for the temporary staffing agency was 1509889. The UPA for the manufacturing firm was 1516843.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR OAR 437-002-0134(12)(C) |
Serious | $1,200 | $1,200 | Mar 4, 2021 | Final |
| Citation 1, item 1b 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $0 | $0 | Mar 4, 2021 | Final |