OSHA SearchOSHA records by employer

Power Construction, LLC: OSHA inspections and violations

Clinton, Maryland · Roofing Contractors · NAICS 238160

3inspections
23citation items
$9,674current penalties
Oct 11, 2019last inspection

OSHA has inspected Power Construction, LLC 3 times in Maryland since 2010.

The latest one began on Oct 11, 2019 as a planned inspection, in Ocean City.

Those inspections ended with 23 citation items: 15 serious, 2 repeat and 6 other-than-serious.

Penalties were first proposed at $9,674 and still stand at $9,674.

Fall protection in construction comes up most often in these citations: 5 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Power Construction, LLC averages $2,812 (2 cited inspections).

Power Construction, LLC: OSHA citation items per year, 2010 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Power Construction, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344375738 OPENED OCT 11, 2019Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 15, 2020

13705 Light House Avenue, Ocean City, MD 21842 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Repeat$2,000$2,000Jan 2, 2020Final
Citation 1, item 2
29 CFR 1926.501(b)(11) · Fall protection in construction
Repeat$2,800$2,800Jan 2, 2020Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Jan 2, 2020Final

Inspection 343786851 OPENED FEB 14, 2019Closed

Planned · Complete · Safety · 7 employees at the site · Closed Apr 17, 2019

26498 Meadowland Ln, Hebron, MD 21830 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.100(a) · Hard hats in construction
Serious$262$262Apr 2, 2019Final
Citation 1, item 1b
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$0$0Apr 2, 2019Final
Citation 1, item 2
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$262$262Apr 2, 2019Final
Citation 1, item 3a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$300$300Apr 2, 2019Final
Citation 1, item 3b
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$0$0Apr 2, 2019Final
Citation 1, item 3c
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0Apr 2, 2019Final

Inspection 314856923 OPENED SEP 14, 2010Open

Planned · Complete · Safety · 4 employees at the site · Open

6822 Sand Cherry Way, Clinton, MD 20735 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$1,050$1,050Oct 28, 2010Open
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Oct 28, 2010Open
Citation 1, item 1c
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Oct 28, 2010Open
Citation 1, item 2
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$600$600Oct 28, 2010Open
Citation 1, item 3
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$900$900Oct 28, 2010Open
Citation 1, item 4a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,050$1,050Oct 28, 2010Open
Citation 1, item 4b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Oct 28, 2010Open
Citation 1, item 4c
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$0$0Oct 28, 2010Open
Citation 1, item 4d
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Oct 28, 2010Open
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$150$150Oct 28, 2010Open
Citation 2, item 2a
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$300$300Oct 28, 2010Open
Citation 2, item 2b
29 CFR 1926.1053(b)(4) · Ladders in construction
Other-than-serious$0$0Oct 28, 2010Open
Citation 2, item 2c
29 CFR 1926.1053(b)(13) · Ladders in construction
Other-than-serious$0$0Oct 28, 2010Open
Citation 2, item 2d
29 CFR 1926.1060(a) · Ladder and stairway training
Other-than-serious$0$0Oct 28, 2010Open

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Maryland