1inspections
4citation items
$4,889current penalties
Dec 14, 2017last inspection

Precast and Stone Concepts, Inc. has one OSHA inspection on record in Florida.

OSHA opened it on Dec 14, 2017 as a planned inspection, in Fort Lauderdale.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $8,148 in penalties. After settlements and reviews the total is $4,889, down 40%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Precast and Stone Concepts, Inc. averages $4,889 over 1 cited inspection in that time.

Precast and Stone Concepts, Inc.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

318employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Precast and Stone Concepts, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342842143 OPENED DEC 14, 2017Closed

Planned · Partial · Safety · 3 employees at the site · Closed Nov 27, 2018

4367 N. Federal Highway, Fort Lauderdale, FL 33308 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,716$1,630Jan 2, 2018Final
Citation 1, item 1b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jan 2, 2018Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,716$1,630Jan 2, 2018Final
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,716$1,630Jan 2, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.