OSHA SearchOSHA records by employer

Precision Composites of Vermont: OSHA inspections and violations

Lyndonville, Vermont · All Other Plastics Product Manufacturing · NAICS 326199

2inspections
4citation items
$675current penalties
Nov 7, 2017last inspection

OSHA has inspected Precision Composites of Vermont 2 times in Vermont since 2015.

The latest one began on Nov 7, 2017 after a complaint, in Lyndonville.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $1,350 and now stand at $675, 50% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Precision Composites of Vermont averages $675 (1 cited inspection).

Precision Composites of Vermont also files yearly injury logs with OSHA, summarized below.

Precision Composites of Vermont: OSHA citation items per year, 2015 to 2017
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

29employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Precision Composites of Vermont and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342758091 OPENED NOV 7, 2017Closed

Complaint · Partial · Health · 20 employees at the site · Closed Nov 22, 2017

630 Gilman Road, Lyndonville, VT 05851 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340523620 OPENED APR 6, 2015Closed

Planned · Complete · Safety · 20 employees at the site · Closed Jun 23, 2015

630 Gilman Road, Lyndonville, VT 05851 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$300$150May 15, 2015Final
Citation 1, item 2
29 CFR 1910.307(c)(3) · Hazardous (classified) locations
Serious$525$262May 15, 2015Final
Citation 1, item 3
29 CFR GENERAL DUTY CLAUSE
Serious$300$150May 15, 2015Final
Citation 1, item 4
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$225$112May 15, 2015Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Lyndonville site logged 1 recordable injury or illness among about 17 workers: 6.8 per 100 full-time workers, against a median of 1.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Precision Composites of Vermont
Lyndonville · 2024
17 106.81.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(j)(1)(i)

(j) Equipment for general use—(1) Lighting fixtures, lampholders, lamps, and receptacles. (i) Fixtures, lampholders, lamps, rosettes, and receptacles may have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 2.44 m (8.0 ft) above the floor may have exposed terminals.

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.307(c)(3)

(3) Safe for the hazardous (classified) location. Equipment that is safe for the location shall be of a type and design that the employer demonstrates will provide protection from the hazards arising from the combustibility and flammability of vapors, liquids, gases, dusts, or fibers involved.

Other all other plastics product manufacturing employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.