Inspection 348336611 OPENED JUN 26, 2025Closed
301 E. Meadowview Road, Greensboro, NC 27406 · Fabric Coating Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Greensboro, North Carolina · Textile and Fabric Finishing Mills · NAICS 313311
Precision Fabrics Group, Inc. has 11 OSHA inspections on record in North Carolina, the first in 1996.
OSHA's last visit started on Jun 26, 2025 to follow up on an earlier case, in Greensboro.
Across those inspections OSHA issued 55 citation items: 8 serious, 1 repeat and 46 other-than-serious.
OSHA proposed $40,416 in penalties. After settlements and reviews the total is $28,768, down 29%.
Most often, OSHA cited 1910.147, lockout/tagout (9 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,875. Precision Fabrics Group, Inc. averages $21,500 over 1 cited inspection in that time.
Precision Fabrics Group, Inc. also files yearly injury logs with OSHA, summarized below.
North Carolina · latest 90 days of OSHA records
236employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Precision Fabrics Group, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Precision Fabrics Group, Inc. at 2 sites in 2 states. Together they've had 21 inspections and $73,948 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans301 E. Meadowview Road, Greensboro, NC 27406 · Fabric Coating Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
301 E. Meadowview Road, Greensboro, NC 27406 · Fabric Coating Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $16,131 | $21,500 | Nov 15, 2024 | Final |
| Citation 1, item 2 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $14,517 | $0 | Nov 15, 2024 | Final |
301 E. Meadowview Rd., Greensboro, NC 27406 · Textile and Fabric Finishing Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Repeat | $180 | $180 | Apr 25, 2011 | Closed |
| Citation 2, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $3,250 | $3,250 | Apr 25, 2011 | Closed |
| Citation 3, item 1 29 CFR 1910.178(a)(6) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Apr 25, 2011 | Closed |
| Citation 3, item 2 29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Apr 25, 2011 | Closed |
| Citation 3, item 3 29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Apr 25, 2011 | Closed |
| Citation 3, item 4 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Apr 25, 2011 | Closed |
| Citation 3, item 5 29 CFR 1910.253(e)(6)(ii) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Apr 25, 2011 | Closed |
3822 Burlington Rd., Greensboro, NC 27405 · Textile and Fabric Finishing Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Other-than-serious | $1,950 | $0 | Apr 8, 2010 | Closed |
| Citation 2, item 1 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Apr 8, 2010 | Closed |
| Citation 2, item 2 29 CFR 1910.157(g)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Apr 8, 2010 | Closed |
| Citation 2, item 3 29 CFR 1910.176(b) · Material storage and aisles |
Other-than-serious | $0 | $0 | Apr 8, 2010 | Closed |
| Citation 2, item 4 29 CFR 1910.178(m)(5)(iii) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Apr 8, 2010 | Closed |
| Citation 2, item 5 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 8, 2010 | Closed |
| Citation 2, item 6 29 CFR 1910.304(g)(6)(vi) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Apr 8, 2010 | Closed |
| Citation 2, item 7 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Apr 8, 2010 | Closed |
| Citation 2, item 8 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Apr 8, 2010 | Closed |
301 E. Meadowview Rd., Greensboro, NC 27406 · Textile and Fabric Finishing Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Serious | $1,750 | $1,200 | Jul 26, 2007 | Closed |
| Citation 1, item 1b 29 CFR 1910.132(f)(3) · Personal protective equipment, general requirements |
Serious | $0 | $0 | Jul 26, 2007 | Closed |
| Citation 1, item 1c 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Serious | $0 | $0 | Jul 26, 2007 | Closed |
| Citation 2, item 1 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 26, 2007 | Closed |
301 E. Meadowview Rd., Greensboro, NC 27406 · Textile and Fabric Finishing Mills · OSHA's record · Phone and website on Google Maps
Incident on Jan 14, 2007: Employee is burned when steam valve fails
On January 14, 2007, Employee #1 was starting up Boiler Number 2 in preparation for plant production. He was injured when an angle gate valve failed on a 10-in. steam line and the boiler room filled with steam. Employee #1 was hospitalized for first-degree and second-degree burns to his left and right arms, fingers, an d torso.
No citations from this inspection.
301 E. Meadowview Rd., Greensboro, NC 27406 · Textile and Fabric Finishing Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $688 | $688 | Apr 14, 2004 | Closed |
| Citation 2, item 1 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Apr 14, 2004 | Closed |
| Citation 2, item 2 29 CFR 1910.176(b) · Material storage and aisles |
Other-than-serious | $0 | $0 | Apr 14, 2004 | Closed |
| Citation 2, item 3 29 CFR 1910.253(e)(6)(ii) · Gas welding and cutting |
Other-than-serious | $0 | $0 | Apr 14, 2004 | Closed |
| Citation 2, item 4 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 14, 2004 | Closed |
301 N. Elm St. Suite 600, Greensboro, NC 27401 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
301 E. Meadowview, Greensboro, NC 27406 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(d)(2) · General requirements |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 2 29 CFR 1910.38(b)(1) · Emergency action plans |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 3 29 CFR 1910.94(c)(2) · Ventilation |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 4 29 CFR 1910.94(c)(3)(ia) · Ventilation |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 5 29 CFR 1910.94(c)(4)(i) · Ventilation |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 6 29 CFR 1910.106(e)(2)(ivd) · Flammable liquids |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 7 29 CFR 1910.147(c)(5)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 8 29 CFR 1910.147(c)(5)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 9 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 10 29 CFR 1910.178(g)(10) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 11 29 CFR 1910.178(k)(1) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 12 29 CFR 1910.178(m)(5)(i) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 13 29 CFR 1910.242(b) · Hand and power tools |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 14 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 15 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 16 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
| Citation 1, item 17 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 30, 1998 | Closed |
301 N. Elm St. Suite 600, Greensboro, NC 27401 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
6012 High Point Rd., Greensboro, NC 27407 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $1,950 | $1,950 | Sep 10, 1996 | Closed |
| Citation 2, item 1 29 CFR 1910.37(k)(2) · Exit routes |
Other-than-serious | $0 | $0 | Sep 10, 1996 | Closed |
| Citation 2, item 2 29 CFR 1910.38(a)(5)(iii) · Emergency action plans |
Other-than-serious | $0 | $0 | Sep 10, 1996 | Closed |
| Citation 2, item 3 29 CFR 1910.147(c)(5)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Sep 10, 1996 | Closed |
| Citation 2, item 4 29 CFR 1910.147(c)(5)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Sep 10, 1996 | Closed |
| Citation 2, item 5 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Sep 10, 1996 | Closed |
| Citation 2, item 6 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Other-than-serious | $0 | $0 | Sep 10, 1996 | Closed |
| Citation 2, item 7 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 10, 1996 | Closed |
| Citation 2, item 8 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Sep 10, 1996 | Closed |
| Citation 2, item 9 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Sep 10, 1996 | Closed |
| Citation 2, item 10 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 10, 1996 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Greensboro site logged 6 recordable injuries or illnesses among about 222 workers: 2.8 per 100 full-time workers, against a median of 2.6 for its industry. Those cases cost 182 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Precision Fabrics Group, Inc Greensboro · 2025 | 222 | 6 | 2 | 2.8 | 2.6 |
| Precision Fabrics Group, Inc-DC Greensboro · 2025 | 54 | 0 | 0 | 0.0 | 2.6 |
| Precision Fabrics Group, Inc (Corporate Office) Greensboro · 2025 | 19 | 0 | 0 | 0.0 | 2.6 |
| Precision Fabrics Group Corporate Office Greensboro · 2024 | 19 | 0 | 0 | 0.0 | 2.6 |
| Precision Fabrics Group - Corporate Greensboro · 2021 | 27 | 0 | 0 | 0.0 | 2.6 |
| Precision Fabrics Group Greensboro · 2018 | 253 | 7 | 2 | 2.8 | 2.6 |
| Precision Fabrics Group - Distribution Center Greensboro · 2018 | 44 | 2 | 0 | 5.9 | 2.6 |
| Precision Fabrics Group Greensboro Plant Greensboro · 2016 | 252 | 15 | 1 | 6.2 | 2.6 |
Included with any plan: 11 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(e)(2)(ivd)
(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.
29 CFR 1910.1200(e)(1)(i)
(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,
29 CFR 1910.1200(h)
(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.