OSHA SearchOSHA records by employer

Precision Steel Manufacturing Corp.: OSHA inspections and violations

Roanoke, Virginia · Fabricated Structural Metal Manufacturing · NAICS 332312

9inspections
31citation items
$8,326current penalties
May 25, 2021last inspection

Since 1996, OSHA inspectors have visited Precision Steel Manufacturing Corp. in Virginia 9 times.

The most recent inspection opened on May 25, 2021 as a planned inspection, in Roanoke.

In all, OSHA issued 31 citation items: 24 serious and 7 other-than-serious.

The proposed penalties came to $13,700; today they stand at $8,326, 39% less.

The rule cited most here is 1910.37 (exit routes), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Precision Steel Manufacturing Corp. averages $1,236 across 1 cited inspection.

Precision Steel Manufacturing Corp. also files yearly injury logs with OSHA, summarized below.

Precision Steel Manufacturing Corp.: OSHA citation items per year, 1996 to 2021
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Precision Steel Manufacturing Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345323125 OPENED MAY 25, 2021Closed

Planned · Complete · Health · 42 employees at the site · Closed Jun 28, 2021

1723 Seibel Drive Nw, Roanoke, VA 24012 · Iron and Steel Mills and Ferroalloy Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$1,765$1,236Jun 2, 2021Final
Citation 2, item 1
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Jun 2, 2021Final

Inspection 317601912 OPENED MAR 26, 2014Closed

Planned · Complete · Health · 54 employees at the site · Closed Apr 25, 2014

1723 Seibel Drive, Roanoke, VA 24012 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Apr 1, 2014Closed
Citation 1, item 2
29 CFR 1910.107(g)(2) · Spray painting and finishing
Other-than-serious$0$0Apr 1, 2014Closed

Inspection 314116559 OPENED FEB 16, 2010Closed

Planned · Complete · Safety · 48 employees at the site · Closed May 5, 2010

1723 Seibel Drive, Roanoke, VA 24012 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(b)(5) · Exit routes
Serious$735$500Apr 15, 2010Closed
Citation 1, item 2 Serious$735$500Apr 15, 2010Closed
Citation 1, item 3
29 CFR 1910.304(f)(1)(iv) · Grounding and circuit protection
Serious$735$500Apr 15, 2010Closed
Citation 1, item 4
29 CFR 1910.107(e)(9) · Spray painting and finishing
Serious$980$411Apr 15, 2010Closed

Inspection 309804706 OPENED JAN 31, 2006Closed

Planned · Complete · Safety · 75 employees at the site · Closed May 4, 2006

1723 Seibel Drive, Roanoke, VA 24012 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$700$400Apr 19, 2006Closed
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Apr 19, 2006Closed
Citation 1, item 2a
29 CFR 1910.37(q)(1) · Exit routes
Serious$525$400Apr 19, 2006Closed
Citation 1, item 2b
29 CFR 1910.37(q)(2) · Exit routes
Serious$0$0Apr 19, 2006Closed
Citation 1, item 2c
29 CFR 1910.36(d)(2) · Exit route design
Serious$0$0Apr 19, 2006Closed
Citation 1, item 3a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$525$400Apr 19, 2006Closed
Citation 1, item 3b
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$0$0Apr 19, 2006Closed
Citation 1, item 3c
29 CFR 1910.304(e)(1)(iv) · Grounding and circuit protection
Serious$0$0Apr 19, 2006Closed
Citation 1, item 3d
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Apr 19, 2006Closed
Citation 1, item 4 Serious$700$300Apr 19, 2006Closed
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$700$390Apr 19, 2006Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Apr 19, 2006Closed

Inspection 305262073 OPENED JUN 27, 2002Closed

Follow-up · Partial · Safety · 30 employees at the site · Closed Jun 27, 2002

1723 Seibel Drive, Roanoke, VA 24012 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304774557 OPENED OCT 9, 2001Closed

Planned · Complete · Safety · 50 employees at the site · Closed May 13, 2002

1723 Seibel Drive, Roanoke, VA 24012 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.38(a)(1) · Emergency action plans
Serious$875$490Dec 19, 2001Closed
Citation 1, item 1b
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0Dec 19, 2001Closed
Citation 1, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$700$490Dec 19, 2001Closed
Citation 1, item 3
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$700$490Dec 19, 2001Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$875$490Dec 19, 2001Closed
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$875$490Dec 19, 2001Closed
Citation 1, item 6
29 CFR 1910.151(c) · First aid and eyewash
Serious$875$490Dec 19, 2001Closed
Citation 2, item 1
29 CFR 1910.106(d)(3)(ii) · Flammable liquids
Other-than-serious$0$0Dec 19, 2001Closed

Inspection 126611037 OPENED JAN 26, 1998Closed

Planned · Complete · Safety · 40 employees at the site · Closed Mar 18, 1998

1723 Seibel Drive, Roanoke, VA 24012 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$700$350Feb 10, 1998Closed
Citation 2, item 1
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Other-than-serious$0$0Feb 10, 1998Closed
Citation 2, item 2
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$0$0Feb 10, 1998Closed

Inspection 126608637 OPENED JAN 28, 1997Closed

Planned · No inspection · Safety · Closed Jan 28, 1997

3193 Rogers Ln., Cloverdale, VA 24077 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

1 older inspection

Inspection 126608363 OPENED SEP 9, 1996Closed

Planned · No inspection · Safety · 30 employees at the site · Closed Sep 9, 1996

3193 Rogers Ln., Cloverdale, VA 24077 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Roanoke site logged 1 recordable injury or illness among about 43 workers: 2.5 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Precision Steel Mfg. Corp.
Roanoke · 2025
43 102.53.6
Precision Steel Mfg.
Roanoke · 2022
42 000.03.6

Included with any plan: 4 more yearly logs from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(ii)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.107(e)(9)

(9) Grounding. Whenever flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) are transferred from one container to another, both containers shall be effectively bonded and grounded to prevent discharge sparks of static electricity.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

Other fabricated structural metal manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.