OSHA SearchOSHA records by employer

Prestige Iron Works: OSHA inspections and violations

Lancaster, South Carolina · Iron and Steel Forging · NAICS 332111

1inspections
3citation items
$0current penalties
Aug 9, 2024last inspection

OSHA inspectors have visited Prestige Iron Works in South Carolina one time.

It opened on Aug 9, 2024 after a complaint, in Lancaster.

In all, OSHA issued 3 citation items: 3 other-than-serious.

No penalty came with these citations.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Prestige Iron Works averages $0 across 1 cited inspection.

Prestige Iron Works: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

42employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Prestige Iron Works and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347680977 OPENED AUG 9, 2024Closed

Complaint · Partial · Safety · 9 employees at the site · Closed Jan 31, 2025

5555 Camp Creek Road, Lancaster, SC 29720 · Iron and Steel Forging · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 18, 2024Final
Citation 1, item 2
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Dec 18, 2024Final
Citation 1, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 18, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(i)

(2) Visual inspection. (i) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord- and plug-connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.

Other iron and steel forging employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.