OSHA SearchOSHA records by employer

Prime Remodeling LLC: OSHA inspections and violations

Baltimore, Maryland · Siding Contractors · NAICS 238170

1inspections
10citation items
$3,150current penalties
Sep 12, 2024last inspection

OSHA inspectors have visited Prime Remodeling LLC in Maryland one time.

It opened on Sep 12, 2024 as a planned inspection, in Baltimore and is still open.

In all, OSHA issued 10 citation items: 9 serious and 1 other-than-serious.

The penalties, $3,150 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Prime Remodeling LLC averages $3,150 across 1 cited inspection.

Prime Remodeling LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

194employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Prime Remodeling LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347749848 OPENED SEP 12, 2024Open

Planned · Complete · Safety · 3 employees at the site · Open

6604 Elsrode Ave, Baltimore, MD 21214 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$1,050$1,050Oct 25, 2024Final
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,050$1,050Oct 25, 2024Final
Citation 1, item 2b
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$0$0Oct 25, 2024Final
Citation 1, item 2c
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Oct 25, 2024Final
Citation 1, item 2d
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Oct 25, 2024Final
Citation 1, item 2e
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Oct 25, 2024Final
Citation 1, item 2f
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Oct 25, 2024Final
Citation 1, item 3a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,050$1,050Oct 25, 2024Final
Citation 1, item 3b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Oct 25, 2024Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Oct 25, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(c)(3)

(3) Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other siding contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.