OSHA SearchOSHA records by employer

Princeton Technology Corp: OSHA inspections and violations

Hudson, New Hampshire · Bare Printed Circuit Board Manufacturing · NAICS 334412

2inspections
6citation items
$8,239current penalties
Jun 23, 2017last inspection

OSHA has inspected Princeton Technology Corp 2 times in New Hampshire since 2017.

The latest one began on Jun 23, 2017 after a complaint, in Hudson.

Those inspections ended with 6 citation items: 6 serious.

Penalties were first proposed at $16,478 and now stand at $8,239, 50% lower after settlements or reviews.

Belts, pulleys and power-transmission parts comes up most often in these citations: 4 items under 1910.219.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Princeton Technology Corp averages $8,239 (1 cited inspection).

Princeton Technology Corp also files yearly injury logs with OSHA, summarized below.

Princeton Technology Corp: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

New Hampshire · latest 90 days of OSHA records

52employers cited

Get notified the morning OSHA posts each new citation in New Hampshire: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Hampshire

Checking a subcontractor, a client or your own company? Watch Princeton Technology Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342420395 OPENED JUN 23, 2017Closed

Complaint · Partial · Health · 50 employees at the site · Closed Dec 5, 2017

33 Constitution Drive, Hudson, NH 03051 · Bare Printed Circuit Board Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342367059 OPENED MAY 24, 2017Closed

Complaint · Partial · Safety · 65 employees at the site · Closed Jan 3, 2020

33 Constitution Drive, Hudson, NH 03051 · Bare Printed Circuit Board Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.29(b)(1) · Fall protection systems in general industry
Serious$6,338$3,169Sep 19, 2017Final
Citation 1, item 2
29 CFR 1910.107(d)(4) · Spray painting and finishing
Serious$5,070$2,535Sep 19, 2017Final
Citation 1, item 3a
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$5,070$2,535Sep 19, 2017Final
Citation 1, item 3b
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Sep 19, 2017Final
Citation 1, item 3c
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Sep 19, 2017Final
Citation 1, item 3d
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Sep 19, 2017Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Hudson site logged 2 recordable injuries or illnesses among about 90 workers: 2.3 per 100 full-time workers, against a median of 0.5 for its industry. Those cases cost 6 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Princeton Technology Corporation
Hudson · 2017
90 222.30.5

Included with any plan: 1 more yearly log from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(d)(4)

(4) Fan-rotating element. The fan-rotating element shall be nonferrous or nonsparking or the casing shall consist of or be lined with such material. There shall be ample clearance between the fan-rotating element and the fan casing to avoid a fire by friction, necessary allowance being made for ordinary expansion and loading to prevent contact between moving parts and the duct or fan housing. Fan blades shall be mounted on a shaft sufficiently heavy to maintain perfect alignment even when the blades of the fan are heavily loaded, the shaft preferably to have bearings outside the duct and booth. All bearings shall be of the self-lubricating type, or lubricated from the outside duct.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(c)(2)(i)

(2) Guarding horizontal shafting. (i) All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.

29 CFR 1910.219(c)(4)(i)

(4) Projecting shaft ends. (i) Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves.

29 CFR 1910.29 · Fall protection systems in general industry

Other bare printed circuit board manufacturing employers in New Hampshire

Alert subscribers get notified of each newly cited employer in New Hampshire the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.