OSHA SearchOSHA records by employer

Prior Lake Machine Inc: OSHA inspections and violations

Prior Lake, Minnesota · Machine Shops · NAICS 332710

7inspections
21citation items
$7,022current penalties
Feb 5, 2021last inspection

Prior Lake Machine Inc has 7 OSHA inspections on record in Minnesota, the first in 1993.

OSHA's last visit started on Feb 5, 2021 as a planned inspection, in Prior Lake.

Across those inspections OSHA issued 21 citation items: 8 serious, 1 repeat and 12 other-than-serious.

OSHA proposed $7,577 in penalties. After settlements and reviews the total is $7,022, down 7%.

Most often, OSHA cited 1910.212, machine guarding (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Prior Lake Machine Inc averages $1,577 over 3 cited inspections in that time.

Prior Lake Machine Inc: OSHA citation items per year, 1993 to 2021
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

373employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Prior Lake Machine Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345161731 OPENED FEB 5, 2021Closed

Planned · Complete · Safety · 14 employees at the site · Closed Apr 8, 2021

16801 Industrial Circle Se, Prior Lake, MN 55372 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Repeat$3,750$3,750Mar 16, 2021Final

Inspection 343628277 OPENED NOV 28, 2018Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Apr 9, 2019

16801 Industrial Circle Se, Prior Lake, MN 55372 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$600$420Dec 6, 2018Final

Inspection 342953098 OPENED FEB 13, 2018Closed

Planned · Complete · Safety · 33 employees at the site · Closed Mar 20, 2018

16801 Industrial Circle Se, Prior Lake, MN 55372 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(b) · Machine guarding
Serious$300$210Feb 27, 2018Final
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$300$210Feb 27, 2018Final
Citation 2, item 1
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$100$70Feb 27, 2018Final
Citation 2, item 2 Other-than-serious$100$70Feb 27, 2018Final

Inspection 317741882 OPENED MAY 14, 2014Closed

Planned · Complete · Safety · 9 employees at the site · Closed May 22, 2014

16801 Industrial Circle Se, Prior Lake, MN 55372 · Machine Shops · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302089180 OPENED APR 28, 1998Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jul 16, 1998

16801 Industrial Circle Se, Prior Lake, MN 55372 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$225$158May 22, 1998Closed
Citation 1, item 2 Serious$225$157May 22, 1998Closed

Inspection 120360441 OPENED DEC 3, 1993Closed

Follow-up · Partial · Safety · 12 employees at the site · Closed Apr 1, 1994

16801 Industrial Circle Se, Prior Lake, MN 55372 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 120415575 OPENED JUL 13, 1993Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jun 6, 1994

16801 Industrial Circle Se, Prior Lake, MN 55372 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(f)(5) · Exit routes
Serious$455$455Aug 12, 1993Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$385$385Aug 12, 1993Closed
Citation 1, item 3
29 CFR 1910.212(a)(5) · Machine guarding
Serious$385$385Aug 12, 1993Closed
Citation 2, item 1
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Aug 12, 1993Closed
Citation 2, item 2 Other-than-serious$0$0Aug 12, 1993Closed
Citation 2, item 3 Other-than-serious$0$0Aug 12, 1993Closed
Citation 2, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 12, 1993Closed
Citation 2, item 5
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Other-than-serious$210$210Aug 12, 1993Closed
Citation 2, item 6 Other-than-serious$0$0Aug 12, 1993Closed
Citation 2, item 7 Other-than-serious$0$0Aug 12, 1993Closed
Citation 2, item 8 Other-than-serious$0$0Aug 12, 1993Closed
Citation 2, item 9 Other-than-serious$262$262Aug 12, 1993Closed
Citation 2, item 10 Other-than-serious$280$280Aug 12, 1993Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1820.6530

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(4)(iii)

(iii) An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.

29 CFR 1910.184 · Slings

29 CFR 1910.184(e)(3)(i)

(3) Inspections. (i) In addition to the inspection required by paragraph (d) of this section, a thorough periodic inspection of alloy steel chain slings in use shall be made on a regular basis, to be determined on the basis of (A) frequency of sling use; (B) severity of service conditions; (C) nature of lifts being made; and (D) experience gained on the service life of slings used in similar circumstances. Such inspections shall in no event be at intervals greater than once every 12 months.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.37 · Exit routes

29 CFR 5205.116

29 CFR 5205.1200

29 CFR 5205.140

29 CFR 5205.675

29 CFR 5205.890

29 CFR 5206.700

Other machine shops employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.