OSHA SearchOSHA records by employer

Pro Construction, Inc.: OSHA inspections and violations

Jacksonville, North Carolina · Commercial and Institutional Building Construction · NAICS 236220

27inspections
82citation items
$21,330current penalties
Aug 22, 2019last inspection

Since 1991, OSHA inspectors have visited Pro Construction, Inc. in North Carolina 27 times.

The most recent inspection opened on Aug 22, 2019 after a complaint, in Raleigh.

In all, OSHA issued 82 citation items: 68 serious and 14 other-than-serious.

The proposed penalties came to $26,875; today they stand at $21,330, 21% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 18 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Pro Construction, Inc. averages $2,000 across 1 cited inspection.

Pro Construction, Inc. also files yearly injury logs with OSHA, summarized below.

Pro Construction, Inc.: OSHA citation items per year, 1991 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Pro Construction, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344257217 OPENED AUG 22, 2019Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Oct 4, 2019

3510 Harden Road, Raleigh, NC 27607 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342757721 OPENED NOV 7, 2017Closed

Referral · Partial · Safety · 2 employees at the site · Closed Feb 7, 2018

206 Greenville Boulevard Sw, Greenville, NC 27834 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$1,000$1,000Jan 22, 2018Final
Citation 1, item 1b
29 CFR 1926.502(b)(3) · Fall protection systems
Serious$0$0Jan 22, 2018Final
Citation 1, item 1c
29 CFR 1926.502(b)(11) · Fall protection systems
Serious$0$0Jan 22, 2018Final
Citation 1, item 2
29 CFR 1926.1053(b)(7) · Ladders in construction
Serious$1,000$1,000Jan 22, 2018Final

Inspection 317275337 OPENED JUL 22, 2013Closed

Planned · Complete · Safety · 1 employee at the site · Closed Oct 30, 2013

1619 Western Blvd., Jacksonville, NC 28546 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$1,500$1,050Aug 23, 2013Closed
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Aug 23, 2013Closed
Citation 1, item 1c
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Aug 23, 2013Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,500$1,050Aug 23, 2013Closed
Citation 1, item 3
29 CFR 1926.451(h)(2) · Scaffolds, general requirements
Serious$450$315Aug 23, 2013Closed
Citation 2, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Other-than-serious$0$0Aug 23, 2013Closed
Citation 2, item 2
29 CFR 1926.405(e)(1) · Job-site wiring
Other-than-serious$0$0Aug 23, 2013Closed

Inspection 317087765 OPENED JUL 5, 2013Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Aug 20, 2013

300 E Main Street, Carrboro, NC 27510 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316361427 OPENED JUN 8, 2012Closed

Planned · Partial · Safety · 1 employee at the site · Closed Sep 14, 2012

1032 Hampton Inn Way, Jacksonville, NC 28546 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(iv) · Fire protection
Other-than-serious$300$300Jul 25, 2012Closed
Citation 1, item 2
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$300$0Jul 25, 2012Closed

Inspection 313214769 OPENED SEP 11, 2009Closed

Planned · Partial · Safety · 51 employees at the site · Closed Sep 25, 2009

1323 Lejeune Blvd, Jacksonville, NC 28540 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311093330 OPENED DEC 10, 2008Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jan 16, 2009

Bldg # 102, Mchugh Blvd., Camp Lejeune, NC 28540 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(a)(4) · Fire protection
Other-than-serious$0$0Jan 9, 2009Closed

Inspection 311093470 OPENED DEC 10, 2008Closed

Planned · Complete · Health · 3 employees at the site · Closed Jan 26, 2009

Bldg # 102, Mchugh Blvd., Camp Lejeune, NC 28540 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

19 older inspections

Inspection 307221135 OPENED MAR 10, 2004Closed

Planned · Partial · Safety · 10 employees at the site · Closed Mar 17, 2004

601 E. 5th Street, Lumberton, NC 28359 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300322609 OPENED MAR 5, 2004Closed

Complaint · Partial · Health · 61 employees at the site · Closed Apr 15, 2004

Camp Lejeune Marine Corps Base, Stone Bay R.range, Camp Lejeune, NC 28542 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$875$650Mar 19, 2004Closed
Citation 1, item 1b
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Mar 19, 2004Closed
Citation 1, item 1c
29 CFR 1910.134(k)(3) · Respiratory protection
Other-than-serious$0$0Mar 19, 2004Closed

Inspection 307220012 OPENED FEB 25, 2004Closed

Planned · Partial · Safety · 80 employees at the site · Closed Mar 2, 2004

710 E Fort Macon Rd., Atlantic Beach, NC 28512 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307266460 OPENED JAN 30, 2004Closed

Complaint · Partial · Health · 2 employees at the site · Closed Nov 18, 2004

3105 Noble Ave, Charlotte, NC 28208 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.1101(f)(2)(i) · Asbestos in construction
Serious$2,450$2,450Apr 8, 2004Final
Citation 1, item 3
29 CFR 1926.1101(g)(1) · Asbestos in construction
Serious$2,450$2,450Apr 8, 2004Final
Citation 1, item 6a
29 CFR 1926.1101(k)(3)(i) · Asbestos in construction
Serious$2,450$2,450Apr 8, 2004Final
Citation 1, item 7
29 CFR 1926.1101(k)(9)(i) · Asbestos in construction
Serious$2,450$2,450Apr 8, 2004Final

Inspection 307215442 OPENED JAN 22, 2004Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 28, 2004

701 W. 9th Street, Southport, NC 28461 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306146598 OPENED APR 24, 2003Closed

Planned · Partial · Safety · 80 employees at the site · Closed May 8, 2003

200 Williamsburg Blvd., Jacksonville, NC 28546 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300321650 OPENED FEB 18, 2003Closed

Planned · Complete · Safety · 4 employees at the site · Closed Apr 4, 2003

4244 Onslow Road, Cherry Point, NC 28533 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$675$300Mar 10, 2003Closed
Citation 1, item 2
29 CFR 1926.405(a)(2)(iii) · Job-site wiring
Serious$675$500Mar 10, 2003Closed
Citation 2, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Mar 10, 2003Closed

Inspection 306140351 OPENED JAN 21, 2003Closed

Planned · Complete · Safety · 103 employees at the site · Closed Feb 7, 2003

501 Cedar Street, Lumberton, NC 28359 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305037889 OPENED JUN 26, 2002Closed

Planned · Complete · Safety · 58 employees at the site · Closed Jul 18, 2002

302b Western Blvd, Jacksonville, NC 28540 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300320678 OPENED MAY 29, 2002Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jul 11, 2002

Corner Of E-street And 4th Avenue, Cherry Point, NC 28533 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.153(k)(2) · Liquefied petroleum gas (LP-Gas)
Serious$1,875$950Jun 14, 2002Closed
Citation 1, item 2a
29 CFR 1926.502(i)(3) · Fall protection systems
Serious$1,125$840Jun 14, 2002Closed
Citation 1, item 2b
29 CFR 1926.502(i)(4) · Fall protection systems
Serious$0$0Jun 14, 2002Closed

Inspection 305037871 OPENED MAY 7, 2002Closed

Planned · Complete · Safety · 130 employees at the site · Closed Jul 2, 2002

200 Hearthstone Drive, Jacksonville, NC 28545 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305195604 OPENED MAR 14, 2002Closed

Planned · Partial · Safety · 1 employee at the site · Closed Apr 8, 2002

3711 Marvin Rd, Charlotte, NC 28211 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$0$0Mar 28, 2002Closed

Inspection 304736606 OPENED DEC 13, 2001Closed

Planned · Complete · Safety · 92 employees at the site · Closed Mar 12, 2002

4500 Blue Clay Rd., Wilmington, NC 28405 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$875$700Jan 31, 2002Closed
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Jan 31, 2002Closed
Citation 1, item 1c
29 CFR 1926.351(b)(2) · Arc welding and cutting
Serious$0$0Jan 31, 2002Closed
Citation 1, item 1d
29 CFR 1926.351(b)(4) · Arc welding and cutting
Serious$0$0Jan 31, 2002Closed
Citation 1, item 1j
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$0$0Jan 31, 2002Closed
Citation 1, item 1k
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$0$0Jan 31, 2002Closed
Citation 1, item 3a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$875$0Jan 31, 2002Closed
Citation 1, item 3c
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Jan 31, 2002Closed
Citation 1, item 3d
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$0$0Jan 31, 2002Closed
Citation 1, item 4a
29 CFR 1926.651(j)(2) · Excavations
Serious$625$500Jan 31, 2002Closed
Citation 1, item 4b
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Jan 31, 2002Closed
Citation 1, item 4c
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Jan 31, 2002Closed
Citation 1, item 4d
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$0$0Jan 31, 2002Closed

Inspection 125317560 OPENED AUG 6, 2001Closed

Planned · Complete · Safety · 6 employees at the site · Closed Sep 19, 2001

3405 Yankee Hall Road, Greenville, NC 27834 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.351(b)(2) · Arc welding and cutting
Other-than-serious$0$0Aug 30, 2001Closed
Citation 1, item 2
29 CFR 1926.451(a)(8) · Scaffolds, general requirements
Other-than-serious$0$0Aug 30, 2001Closed

Inspection 304262603 OPENED JUL 25, 2001Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Sep 28, 2001

Old Country Club Rd., Jacksonville, NC 28546 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$525$420Aug 13, 2001Closed
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Aug 13, 2001Closed
Citation 1, item 1c
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$0$0Aug 13, 2001Closed
Citation 1, item 1d
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Aug 13, 2001Closed
Citation 1, item 1e
29 CFR 1926.550(a)(1) · [Reserved]
Serious$0$0Aug 13, 2001Closed
Citation 1, item 1f
29 CFR 1926.550(a)(5) · [Reserved]
Serious$0$0Aug 13, 2001Closed
Citation 1, item 1g
29 CFR 1926.550(a)(5) · [Reserved]
Serious$0$0Aug 13, 2001Closed
Citation 1, item 1h
29 CFR 1926.550(a)(9) · [Reserved]
Serious$0$0Aug 13, 2001Closed
Citation 1, item 1i
29 CFR 1926.100(a) · Hard hats in construction
Serious$0$0Aug 13, 2001Closed
Citation 1, item 2a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$525$420Aug 13, 2001Closed
Citation 1, item 2b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0Aug 13, 2001Closed
Citation 1, item 2c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Aug 13, 2001Closed
Citation 1, item 2d
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Aug 13, 2001Closed
Citation 1, item 2e
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Aug 13, 2001Closed
Citation 1, item 2f
29 CFR 1926.451(h)(2)(i) · Scaffolds, general requirements
Serious$0$0Aug 13, 2001Closed
Citation 1, item 2g
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Aug 13, 2001Closed
Citation 1, item 2h
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Aug 13, 2001Closed
Citation 1, item 2i
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Aug 13, 2001Closed

Inspection 302875729 OPENED DEC 15, 1999Closed

Unprogrammed related · Partial · Health · 8 employees at the site · Closed Jul 24, 2000

1828 Trailwood Drive, Raleigh, NC 27606 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$350$350May 3, 2000Closed
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0May 3, 2000Closed
Citation 1, item 1c
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0May 3, 2000Closed
Citation 1, item 1d
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0May 3, 2000Closed
Citation 1, item 1e
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0May 3, 2000Closed
Citation 1, item 1f
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0May 3, 2000Closed
Citation 1, item 1g
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0May 3, 2000Closed
Citation 1, item 1h
29 CFR 1926.454(b) · Scaffold training
Serious$0$0May 3, 2000Closed

Inspection 302873799 OPENED NOV 17, 1999Closed

Unprogrammed related · Partial · Safety · 15 employees at the site · Closed Feb 7, 2000

1828 Trailwood Drive, Raleigh, NC 27606 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$175$140Dec 8, 1999Closed
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Dec 8, 1999Closed
Citation 1, item 1c
29 CFR 1926.105(a) · Safety nets
Serious$0$0Dec 8, 1999Closed
Citation 1, item 2a
29 CFR 1926.706(a)(5) · Requirements for masonry construction
Serious$100$80Dec 8, 1999Closed
Citation 1, item 2b
29 CFR 1926.706(b) · Requirements for masonry construction
Serious$0$0Dec 8, 1999Closed
Citation 1, item 2c
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Dec 8, 1999Closed

Inspection 109468207 OPENED MAY 18, 1995Closed

Planned · Partial · Safety · 10 employees at the site · Closed Jun 20, 1995

Camp Lejeune Marine Corps Base, Stone Bay R.range, Camp Lejeune, NC 28542 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 17464355 OPENED APR 4, 1991Closed

Planned · Complete · Safety · 47 employees at the site · Closed Jan 4, 1992

Building 400 Mcas, Cherry Point, NC 28533 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.59(e)(1) · Hazard communication
Serious$525$290Jun 6, 1991Contested
Citation 1, item 1b
29 CFR 1926.59(g)(8) · Hazard communication
Serious$0$0Jun 6, 1991Contested
Citation 1, item 1c
29 CFR 1926.59(h) · Hazard communication
Serious$0$0Jun 6, 1991Contested
Citation 1, item 2a
29 CFR 1926.404(f)(7)(ivc) · Ground-fault protection on job sites
Serious$1,225$675Jun 6, 1991Final
Citation 1, item 2b
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$0$0Jun 6, 1991Contested
Citation 1, item 2c
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Jun 6, 1991Contested
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Jun 6, 1991Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2020, the Jacksonville site logged 0 recordable injuries or illnesses among about 8 workers: 0.0 per 100 full-time workers, against a median of 0.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Pro Construction, Inc.
Jacksonville · 2020
8 000.00.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(1)

(1) Normal breathing. In a normal standing position, without talking, the subject shall breathe normally.

29 CFR 1910.134(k)(3)

(3) The employer shall provide the training prior to requiring the employee to use a respirator in the workplace.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.105 · Safety nets

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1101 · Asbestos in construction

29 CFR 1926.150 · Fire protection

29 CFR 1926.153 · Liquefied petroleum gas (LP-Gas)

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.25 · Housekeeping

29 CFR 1926.351 · Arc welding and cutting

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.550 · [Reserved]

29 CFR 1926.59 · Hazard communication

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.706 · Requirements for masonry construction

Other commercial and institutional building construction employers in North Carolina