Inspection 347187155 OPENED DEC 29, 2023Closed
521 London Bridge Road, Virginia Beach, VA 23454 · Truck Trailer Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Virginia Beach, Virginia · Truck Trailer Manufacturing · NAICS 336212
OSHA has inspected Pro Fabrication Inc. 2 times in Virginia since 2022.
The latest one began on Dec 29, 2023 to follow up on an earlier case, in Virginia Beach.
Those inspections ended with 23 citation items: 20 serious and 3 other-than-serious.
Penalties were first proposed at $27,865 and now stand at $18,118, 35% lower after settlements or reviews.
Electrical wiring methods comes up most often in these citations: 5 items under 1910.305.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Pro Fabrication Inc. averages $18,118 (1 cited inspection).
Virginia · latest 90 days of OSHA records
248employers cited
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch Pro Fabrication Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company521 London Bridge Road, Virginia Beach, VA 23454 · Truck Trailer Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
521 London Bridge Road, Virginia Beach, VA 23454 · Truck Trailer Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(1) · Walking-working surfaces |
Serious | $1,570 | $1,099 | Apr 25, 2023 | Final |
| Citation 1, item 2a 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Serious | $2,180 | $1,526 | Apr 25, 2023 | Final |
| Citation 1, item 2b 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Serious | $0 | $0 | Apr 25, 2023 | Final |
| Citation 1, item 3 29 CFR 1910.176(b) · Material storage and aisles |
Serious | $1,840 | $1,288 | Apr 25, 2023 | Final |
| Citation 1, item 4 29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks |
Serious | $2,855 | $1,998 | Apr 25, 2023 | Final |
| Citation 1, item 5a 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $2,855 | $1,998 | Apr 25, 2023 | Final |
| Citation 1, item 5b 29 CFR 1910.212(b) · Machine guarding |
Serious | $0 | $0 | Apr 25, 2023 | Final |
| Citation 1, item 5c 29 CFR 1910.215(a)(1) · Grinders and abrasive wheels |
Serious | $0 | $0 | Apr 25, 2023 | Final |
| Citation 1, item 5d 29 CFR 1910.243(c)(3) · Guarding of portable powered tools |
Serious | $0 | $0 | Apr 25, 2023 | Final |
| Citation 1, item 7 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Serious | $2,855 | $1,998 | Apr 25, 2023 | Final |
| Citation 1, item 8 29 CFR 1910.303(h)(3) · Electrical equipment, general requirements |
Serious | $2,410 | $1,687 | Apr 25, 2023 | Final |
| Citation 1, item 9a 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Serious | $2,855 | $1,998 | Apr 25, 2023 | Final |
| Citation 1, item 9b 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $0 | Apr 25, 2023 | Final |
| Citation 1, item 9c 29 CFR 1910.305(g)(1)(iv)(b) · Electrical wiring methods |
Serious | $0 | $0 | Apr 25, 2023 | Final |
| Citation 1, item 9d 29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods |
Serious | $0 | $0 | Apr 25, 2023 | Final |
| Citation 1, item 9e 29 CFR 1910.305(g)(1)(iv)(e) · Electrical wiring methods |
Serious | $0 | $0 | Apr 25, 2023 | Final |
| Citation 1, item 10a 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Serious | $2,855 | $1,998 | Apr 25, 2023 | Final |
| Citation 1, item 10b 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Apr 25, 2023 | Final |
| Citation 1, item 11a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $2,180 | $1,526 | Apr 25, 2023 | Final |
| Citation 1, item 11b 29 CFR 1910.1200(f)(6)(ii) · Hazard communication |
Serious | $0 | $0 | Apr 25, 2023 | Final |
| Citation 2, item 1 29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting |
Other-than-serious | $2,410 | $0 | Apr 25, 2023 | Final |
| Citation 2, item 2a 29 CFR 16VAC25-60-307.D.1 |
Other-than-serious | $1,000 | $1,000 | Nov 3, 2023 | Final |
| Citation 2, item 2b 29 CFR 16VAC25-60-307.E.1 |
Other-than-serious | $0 | $0 | Nov 3, 2023 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.1200(f)(6)(ii)
(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.
29 CFR 1910.157(c)(1)
(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.