Pro Painting & Drywall SVCS, LLC: OSHA inspections and violations

Magnolia, Texas · Painting and Wall Covering Contractors · NAICS 238320

1inspections
2citation items
$4,475current penalties
Apr 7, 2022last inspection

OSHA inspectors have visited Pro Painting & Drywall SVCS, LLC in Texas one time.

It opened on Apr 7, 2022 as a planned inspection, in Magnolia.

In all, OSHA issued 2 citation items: 2 serious.

The proposed penalties came to $7,459; today they stand at $4,475, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Pro Painting & Drywall SVCS, LLC averages $4,475 across 1 cited inspection.

Pro Painting & Drywall SVCS, LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

405employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Pro Painting & Drywall SVCS, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345882369 OPENED APR 7, 2022Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jul 8, 2022

5520 Fm 1488, Magnolia, TX 77354 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Serious$3,315$1,989May 31, 2022Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,144$2,486May 31, 2022Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.