OSHA SearchOSHA records by employer

Puerto Rico Steel Products Corp: OSHA inspections and violations

Coto Laurel, Puerto Rico · Steel Wire Drawing · NAICS 331222

6inspections
31citation items
$29,332current penalties
Jun 12, 2025last inspection

OSHA has inspected Puerto Rico Steel Products Corp 6 times in Puerto Rico since 2005.

The latest one began on Jun 12, 2025 on a referral, in Coto Laurel.

Those inspections ended with 31 citation items: 23 serious, 1 repeat and 7 other-than-serious.

Penalties were first proposed at $45,134 and now stand at $29,332, 35% lower after settlements or reviews.

Personal protective equipment, general requirements comes up most often in these citations: 5 items under 1910.132.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Puerto Rico Steel Products Corp averages $6,979 (4 cited inspections).

Puerto Rico Steel Products Corp also files yearly injury logs with OSHA, summarized below.

Puerto Rico Steel Products Corp: OSHA citation items per year, 2005 to 2025
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

114employers cited

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch Puerto Rico Steel Products Corp and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348305210 OPENED JUN 12, 2025Closed

Referral · Partial · Safety · 39 employees at the site · Closed Aug 25, 2026

Carretera 511 Km 1.2 1011 Coral Falso, Coto Laurel, PR 00780 · Steel Wire Drawing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 6 A
Serious$2,100$1,470Dec 1, 2025Final
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$4,900$3,430Dec 1, 2025Final
Citation 1, item 3
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$3,500$2,450Dec 1, 2025Final
Citation 1, item 4
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$3,500$2,450Dec 1, 2025Final
Citation 1, item 5
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$1,750$1,225Dec 1, 2025Final
Citation 1, item 6
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$4,900$3,430Dec 1, 2025Final
Citation 2, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Repeat$9,800$6,860Dec 1, 2025Final

Inspection 347427288 OPENED APR 16, 2024Closed

Referral · Partial · Safety · 42 employees at the site · Closed Oct 31, 2024

Carretera 511 Km 1.2, Coto Laurel, PR 00780 · Steel Wire Drawing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(c) · Personal protective equipment, general requirements
Serious$3,500$2,083Sep 16, 2024Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Sep 16, 2024Final

Inspection 346151376 OPENED AUG 16, 2022Closed

Complaint · Partial · Safety · 40 employees at the site · Closed Feb 6, 2023

Carretera 511 Km 1.2, Coto Laurel, PR 00780 · Steel Wire Drawing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$1,785$1,071Dec 12, 2022Final
Citation 1, item 1b
29 CFR 1910.133(a)(3) · Eye and face protection
Serious$0$0Dec 12, 2022Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,083$1,250Dec 12, 2022Final
Citation 1, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$1,785$1,071Dec 12, 2022Final

Inspection 343148565 OPENED APR 24, 2018Closed

Complaint · Partial · Health · 30 employees at the site · Closed Oct 15, 2018

Carretera 511 Km 1.2, Coto Laurel, PR 00780 · Steel Wire Drawing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$750$375Jul 20, 2018Final
Citation 1, item 2
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$750$375Jul 20, 2018Final
Citation 1, item 3
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$750$375Jul 20, 2018Final
Citation 2, item 1
29 CFR 1904 2 A
Other-than-serious$500$0Jul 20, 2018Final
Citation 2, item 2
29 CFR 1904 2 A
Other-than-serious$500$0Jul 20, 2018Final
Citation 2, item 3
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Jul 20, 2018Final
Citation 2, item 4
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Jul 20, 2018Final
Citation 2, item 5
29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Jul 20, 2018Final

Inspection 309960698 OPENED MAY 20, 2009Closed

Complaint · Complete · Safety · 17 employees at the site · Closed Sep 3, 2009

3083 El Tuque Insdustrial Park Road 591, Ponce, PR 00728 · Other Fabricated Wire Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a)(3) · Exit routes
Serious$225$135Jun 3, 2009Closed
Citation 1, item 2
29 CFR 1910.37(b)(2) · Exit routes
Serious$225$135Jun 3, 2009Closed
Citation 1, item 3 Serious$225$135Jun 3, 2009Closed
Citation 1, item 4 Serious$225$135Jun 3, 2009Closed
Citation 1, item 5
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$225$135Jun 3, 2009Closed
Citation 2, item 1
29 CFR 6A0001
Other-than-serious$120$120Jun 3, 2009Closed

Inspection 306668559 OPENED OCT 17, 2005Closed

Complaint · Complete · Safety · 22 employees at the site · Closed Dec 5, 2005

Carr 591 Zona Industrial El Tuque, Ponce, PR 00728 · Rolled Steel Shape Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 6A0001
Serious$318$191Oct 31, 2005Closed
Citation 1, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$318$191Nov 1, 2005Closed
Citation 2, item 1
29 CFR 1700II0A04
Serious$200$120Nov 1, 2005Closed
Citation 2, item 2
29 CFR 1700IV0A01
Serious$200$120Nov 1, 2005Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Coto Laurel site logged 6 recordable injuries or illnesses among about 48 workers: 12.5 per 100 full-time workers, against a median of 5.4 for its industry. Those cases cost 126 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Puerto Rico Steel Products Corp
Coto Laurel · 2025
48 6512.55.4

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other steel wire drawing employers in Puerto Rico

Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.