Pullman Power, LLC has 7 OSHA inspections on record in West Virginia, the first in 2001.

OSHA's last visit started on Jan 11, 2024 as a planned inspection, in Huntington.

Across those inspections OSHA issued 9 citation items: 2 serious and 7 other-than-serious.

OSHA proposed $83,600 in penalties. After settlements and reviews the total is $80,000, down 4%.

Most often, OSHA cited 1926.602, earthmovers and forklifts in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Pullman Power, LLC averages $0 over 1 cited inspection in that time.

2 inspections on this page followed a fatal incident.

Pullman Power, LLC: OSHA citation items per year, 2001 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Pullman Power, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347208209 OPENED JAN 11, 2024Closed

Planned · Complete · Safety · 50 employees at the site · Closed Feb 14, 2024

750 5th Avenue, Huntington, WV 25701 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344448915 OPENED OCT 9, 2019Closed

Unprogrammed related · Partial · Safety · 480 employees at the site · Closed Jun 4, 2020

State Capitol Bldg 1900 Kanawha Blvd E, Charleston, WV 25305 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1926.34(b) · Means of egress
Other-than-serious$0$0Mar 3, 2020Final

Inspection 116527151 OPENED SEP 15, 2007Closed

Accident · Complete · Safety · 25 employees at the site · Closed Oct 4, 2007

Allegheny Energy Supply / Power Station Blvd, Willow Island, WV 26134 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

Incident on Sep 15, 2007 (fatal): Employee killed in fall from power plant walkway

On September 15, 2007, Employee #1 and coworkers were working in a newly constru cted 600 ft tall stack at a power plant. The crew noticed that the lighting was dimmer than usual, and Employee #1 and a coworker were sent to an approximately 203 ft high metal walkway to see what the problem might be. They used a man-hois t and an aluminum pick to reach the walkway. Employee #1 separated from his cowo rker and was near the end of the walkway next to a ladder when the coworker hear d a loud noise. Another coworker on a lower level shouted, "Man down!" Employee #1 was found on the concrete floor; he died of injuries sustained in the fall. E mployee #1 was using fall protection and was apparently tied off to a horizontal lifeline while in the hoist, but it was unclear whether he tied off to another line on the walkway. The walkway had an opening for a material hoist. When Emplo yee #1's body was found, both lanyards attached to the right D-ring.

No citations from this inspection.

Inspection 309475846 OPENED MAY 31, 2007Closed

Unprogrammed related · Partial · Health · 37 employees at the site · Closed Feb 11, 2016

Route 35, St Albans, WV 25177 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309469617 OPENED JAN 22, 2007Closed

Planned · Partial · Safety · 25 employees at the site · Closed Mar 14, 2007

Aep - John Amos Plant, St Albans, WV 25177 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.602(c)(1)(vi) · Earthmovers and forklifts in construction
Other-than-serious$4,000$0Feb 5, 2007Closed
Citation 1, item 2
29 CFR 1926.602(c)(1)(ii) · Earthmovers and forklifts in construction
Other-than-serious$4,000$0Feb 5, 2007Closed

Inspection 307067793 OPENED MAR 5, 2006Closed

Accident · Complete · Safety · 21 employees at the site · Closed Feb 4, 2008

Route 35, St Albans, WV 25177 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Incident on Mar 5, 2006 (fatal): Employee dies in smoke stack fire

On March 5, 2006, a fire started inside the 974-ft smoke stack while employees w ere installing a fiberglass liner. Employee #1 was trapped inside, and found dea d in the man cage he had tried to use to exit the smoke stack.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1b
29 CFR 1926.407(b)(2)(i) · Hazardous (classified) locations
Serious$0$5,000Aug 31, 2006Final
Citation 1, item 2
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Other-than-serious$6,300$2,500Aug 31, 2006Final
Citation 1, item 4
OSH Act Section 5(a)(1) · General Duty Clause
Serious$6,300$7,000Aug 31, 2006Final
Citation 1, item 8a
29 CFR 1926.21(b)(2) · Construction safety training
Other-than-serious$0$2,500Aug 31, 2006Final
Citation 1, item 8b
29 CFR 1910.1200(h)(2)(ii) · Hazard communication
Other-than-serious$0$0Aug 31, 2006Final
Citation 2, item 1
29 CFR 1926.151(a)(3) · Fire prevention
Unclassified$63,000$63,000Aug 31, 2006Final

Inspection 116492570 OPENED OCT 3, 2001Closed

Unprogrammed related · Partial · Safety · 43 employees at the site · Closed Oct 19, 2001

555 Beechurst Drive, Morgantown, WV 26505 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(2)(ii)

(ii) Any operations in their work area where hazardous chemicals are present; and,

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(d)(1)(iii)

(iii) The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH.

29 CFR 1926.151 · Fire prevention

29 CFR 1926.151(a)(3)

(3) Smoking shall be prohibited at or in the vicinity of operations which constitute a fire hazard, and shall be conspicuously posted: “No Smoking or Open Flame.”

29 CFR 1926.21 · Construction safety training

29 CFR 1926.34 · Means of egress

29 CFR 1926.407 · Hazardous (classified) locations

29 CFR 1926.602 · Earthmovers and forklifts in construction

OSH Act Section 5 · General Duty Clause

Other industrial building construction employers in West Virginia

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.