OSHA SearchOSHA records by employer

Purgatoire Valley Construction: OSHA inspections and violations

Kit Carson, Colorado · Water and Sewer Line and Related Structures Construction · NAICS 237110

5inspections
20citation items
$16,358current penalties
Aug 10, 2015last inspection

Purgatoire Valley Construction has 5 OSHA inspections on record in Colorado, the first in 2007.

OSHA's last visit started on Aug 10, 2015 after a complaint, in Trinidad.

Across those inspections OSHA issued 20 citation items: 5 serious and 15 other-than-serious.

OSHA proposed $26,275 in penalties. After settlements and reviews the total is $16,358, down 38%.

Most often, OSHA cited 1926.1101, asbestos in construction (8 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Purgatoire Valley Construction averages $3,850 over 1 cited inspection in that time.

Purgatoire Valley Construction: OSHA citation items per year, 2007 to 2015
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

138employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Purgatoire Valley Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340838234 OPENED AUG 10, 2015Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Jun 21, 2016

Commercial Street & Cedar, Trinidad, CO 81082 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.28(a) · Personal protective equipment
Serious$2,800$1,400Aug 18, 2015Final
Citation 1, item 2
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,900$2,450Aug 18, 2015Final

Inspection 313722001 OPENED AUG 19, 2010Closed

Referral · Partial · Safety · 80 employees at the site · Closed Mar 14, 2011

606 Highway 59, Kit Carson, CO 80825 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Other-than-serious$3,000$2,500Sep 29, 2010Closed
Citation 1, item 2a
29 CFR 1926.1053(b)(4) · Ladders in construction
Other-than-serious$1,200$500Sep 29, 2010Closed
Citation 1, item 2b
29 CFR 1926.1060(a)(1) · Ladder and stairway training
Other-than-serious$0$0Sep 29, 2010Closed

Inspection 110486719 OPENED JAN 26, 2010Closed

Complaint · Complete · Safety · 5 employees at the site · Closed Mar 2, 2010

606 Hwy 59, Kit Carson, CO 80825 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.200(g)(1) · Accident prevention signs and tags
Other-than-serious$3,000$2,700Feb 23, 2010Closed
Citation 1, item 2a
29 CFR 1926.1053(b)(3) · Ladders in construction
Other-than-serious$900$810Feb 23, 2010Closed
Citation 1, item 2b
29 CFR 1926.1053(b)(15) · Ladders in construction
Other-than-serious$0$0Feb 23, 2010Closed
Citation 1, item 2c
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0Feb 23, 2010Closed

Inspection 313717126 OPENED JAN 26, 2010Closed

Complaint · Partial · Health · 5 employees at the site · Closed Apr 15, 2010

606 Hwy 59, Kit Carson, CO 80825 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.1101(e)(1) · Asbestos in construction
Other-than-serious$1,125$1,012Feb 23, 2010Closed
Citation 1, item 2b
29 CFR 1926.1101(k)(3)(i) · Asbestos in construction
Other-than-serious$0$0Feb 23, 2010Closed
Citation 1, item 2c
29 CFR 1926.1101(k)(7)(i) · Asbestos in construction
Other-than-serious$0$0Feb 23, 2010Closed
Citation 1, item 2d
29 CFR 1926.1101(k)(9)(ivc) · Asbestos in construction
Other-than-serious$0$0Feb 23, 2010Closed
Citation 1, item 3
29 CFR 1926.1101(f)(2)(i) · Asbestos in construction
Other-than-serious$1,125$1,012Feb 23, 2010Closed
Citation 1, item 4a
29 CFR 1926.1101(g)(8)(vd) · Asbestos in construction
Other-than-serious$1,125$1,012Feb 23, 2010Closed
Citation 1, item 4b
29 CFR 1926.1101(l)(2) · Asbestos in construction
Other-than-serious$0$0Feb 22, 2010Closed
Citation 1, item 5
29 CFR 1926.1101(o)(1) · Asbestos in construction
Other-than-serious$1,125$1,012Feb 22, 2010Closed

Inspection 110483708 OPENED APR 19, 2007Closed

Unprogrammed other · Partial · Safety · 9 employees at the site · Closed May 31, 2007

21-17 Hill Ranch 36-2, Segundo, CO 81082 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.200(g)(2) · Accident prevention signs and tags
Serious$3,500$1,400May 7, 2007Closed
Citation 1, item 2
29 CFR 1926.651(d) · Excavations
Serious$1,100$0May 7, 2007Closed
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$1,375$550May 7, 2007Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(15)

(15) Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1053(b)(3)

(3) Ladders shall not be loaded beyond the maximum intended load for which they were built, nor beyond their manufacturer's rated capacity.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1101 · Asbestos in construction

29 CFR 1926.200 · Accident prevention signs and tags

29 CFR 1926.28 · Personal protective equipment

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.