Inspection 341684298 OPENED AUG 8, 2016Closed
Calle Amalia Marin Int Munoz Rivera, Penuelas, PR 00624 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Penuelas, Puerto Rico · Commercial and Institutional Building Construction · NAICS 236220
OSHA has inspected Quality Construction II LLC 2 times in Puerto Rico since 2016.
The latest one began on Aug 8, 2016 on a referral, in Penuelas.
Those inspections ended with 3 citation items: 1 serious and 2 other-than-serious.
Penalties were first proposed at $1,823 and now stand at $473, 74% lower after settlements or reviews.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Quality Construction II LLC averages $473 (1 cited inspection).
Puerto Rico · latest 90 days of OSHA records
109employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Puerto Rico
Checking a subcontractor, a client or your own company? Watch Quality Construction II LLC and get notified the morning OSHA posts a new citation for it.
Watch this companyCalle Amalia Marin Int Munoz Rivera, Penuelas, PR 00624 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Calle Amalia Marin Inteseccion Ave Luis Munoz Rivera, Penuelas, PR 00624 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $473 | $473 | Jul 15, 2016 | Final |
| Citation 1, item 2 29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements |
Other-than-serious | $675 | $0 | Jul 15, 2016 | Final |
| Citation 1, item 3 29 CFR 1926.454(b)(2) · Scaffold training |
Other-than-serious | $675 | $0 | Jul 15, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.404(b)(1)(ii)
(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.
29 CFR 1926.451(c)(2)(i)
(i) Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.
29 CFR 1926.454(b)(2)
(2) The correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in question;
Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.