Inspection 345115364 OPENED JAN 21, 2021Closed
4811 Venture Dr, Sheboygan, WI 53083 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 1984, OSHA inspectors have visited Quasius Construction, Inc in Wisconsin 10 times.
The most recent inspection opened on Jan 21, 2021 on a referral, in Sheboygan.
In all, OSHA issued 9 citation items: 5 serious and 4 other-than-serious.
The proposed penalties came to $14,123; today they stand at $6,956, 51% less.
The rule cited most here is 1926.501 (fall protection in construction), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Quasius Construction, Inc averages $3,816 across 1 cited inspection.
Quasius Construction, Inc also files yearly injury logs with OSHA, summarized below.
Wisconsin · latest 90 days of OSHA records
229employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Wisconsin
Checking a subcontractor, a client or your own company? Watch Quasius Construction, Inc and get notified the morning OSHA posts a new citation for it.
Watch this company4811 Venture Dr, Sheboygan, WI 53083 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
N Water St And Wisconsin Ave, Sheboygan, WI 53081 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
133 E. Mill St., Plymouth, WI 53073 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.62(d)(1)(i) · Lead in construction |
Other-than-serious | $4,771 | $2,386 | Jan 6, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.1053(b)(16) · Ladders in construction |
Other-than-serious | $2,862 | $1,431 | Jan 6, 2017 | Final |
1280 Pine Haven Ln, Sheboygan Falls, WI 53085 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1290 North Ave. Ltc, Cleveland, WI 53015 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1236 N. 18th St, Sheboygan, WI 53081 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Sheboygan Ymca, Sheboygan, WI 53081 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1607 Geele Avenue, Sheboygan, WI 53081 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $1,250 | $625 | Jun 2, 2010 | Closed |
1160 Fond Du Lac Ave., Sheboygan Falls, WI 53085 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $2,500 | $1,250 | Jul 19, 2005 | Final |
| Citation 1, item 2 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $1,250 | $625 | Jul 19, 2005 | Final |
| Citation 1, item 3 29 CFR 1926.501(b)(14) · Fall protection in construction |
Serious | $1,250 | $400 | Jul 19, 2005 | Final |
| Citation 2, item 1 29 CFR 1926.50(d)(2) · Medical services and first aid |
Other-than-serious | $0 | $0 | Jul 19, 2005 | Final |
727 Plaza 8, Sheboygan, WI 53081 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(d)(10) · Scaffolds, general requirements |
Serious | $240 | $240 | Mar 7, 1984 | Closed |
| Citation 2, item 1 29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements |
Other-than-serious | $0 | $0 | Mar 7, 1984 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Sheboygan site logged 0 recordable injuries or illnesses among about 69 workers: 0.0 per 100 full-time workers, against a median of 0.6 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Quasius Construction Sheboygan · 2025 | 69 | 0 | 0 | 0.0 | 0.6 |
Included with any plan: 1 more yearly log from these sites, back to 2024, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(16)
(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.
29 CFR 1926.300(b)(2)
(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.
29 CFR 1926.451(d)(10)
(10) Ropes shall be inspected for defects by a competent person prior to each workshift and after every occurrence which could affect a rope's integrity. Ropes shall be replaced if any of the following conditions exist:
Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.