OSHA SearchOSHA records by employer

Quietaire Corporation: OSHA inspections and violations

Houston, Texas · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · NAICS 333413

3inspections
18citation items
$18,970current penalties
Jul 12, 2016last inspection

Since 1976, OSHA inspectors have visited Quietaire Corporation in Texas 3 times.

The most recent inspection opened on Jul 12, 2016 on a referral, in Houston.

In all, OSHA issued 18 citation items: 8 serious, 1 repeat and 9 other-than-serious.

The proposed penalties came to $36,839; today they stand at $18,970, 49% less.

The rule cited most here is 1910.212 (machine guarding), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Quietaire Corporation averages $9,440 across 2 cited inspections.

Quietaire Corporation also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Quietaire Corporation: OSHA citation items per year, 1976 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Quietaire Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341621506 OPENED JUL 12, 2016Closed

Referral · Complete · Safety · 19 employees at the site · Closed Nov 16, 2017

505 N. Hutcheson St., Houston, TX 77003 · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$3,135$1,500Dec 23, 2016Final
Citation 1, item 2a Serious$4,703$1,526Dec 23, 2016Final
Citation 1, item 2b Serious$0$0Dec 23, 2016Final
Citation 1, item 2c Serious$2,850$0Dec 23, 2016Final
Citation 1, item 4
29 CFR 1910.212(a)(5) · Machine guarding
Serious$3,920$1,000Dec 23, 2016Final
Citation 1, item 5
29 CFR 1910.213(g)(1) · Woodworking machinery
Serious$5,487$1,000Dec 23, 2016Final
Citation 2, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Repeat$10,974$10,974Dec 23, 2016Final
Citation 3, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$440$0Dec 23, 2016Final
Citation 3, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$440$0Dec 23, 2016Final

Inspection 341168581 OPENED JAN 7, 2016Closed

Planned · Partial · Safety · 12 employees at the site · Closed Jun 16, 2016

505 N. Hutcheson St., Houston, TX 77003 · Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$2,400$1,440May 27, 2016Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$2,400$1,440May 27, 2016Final

Inspection 16783987 OPENED FEB 4, 1976Closed

Planned · Complete · Safety · 27 employees at the site · Closed Mar 30, 1976

505 N Hutcheson, Houston, TX 77003 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Feb 23, 1976Closed
Citation 1, item 2
29 CFR 1910.107(c)(6) · Spray painting and finishing
Other-than-serious$0$0Feb 23, 1976Closed
Citation 1, item 3 Other-than-serious$0$0Feb 23, 1976Closed
Citation 1, item 4
29 CFR 1910.179(b)(5) · Overhead and gantry cranes
Other-than-serious$0$0Feb 23, 1976Closed
Citation 1, item 5
29 CFR 1910.213(g)(1) · Woodworking machinery
Other-than-serious$30$30Feb 23, 1976Closed
Citation 1, item 6 Other-than-serious$30$30Feb 23, 1976Closed
Citation 1, item 7 Other-than-serious$30$30Feb 23, 1976Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2017, the Houston site logged 0 recordable injuries or illnesses among about 17 workers: 0.0 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Quietaire Corp
Houston · 2017
17 000.03.6

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jul 6, 2016, Houston: Hospitalization · soreness, pain, hurt-nonspecified injury · finger(s), fingernail(s), unspecified

An employee was working on a press brake when his right hand became caught between the dies in the machine, injuring his index, middle, and ring fingers on his right hand.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.309

Other industrial and commercial fan and blower and air purification equipment manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.