Inspection 348810300 OPENED FEB 20, 2026Closed
220 East Oliver Road, Homestead, PA 15120 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Pittsburgh, Pennsylvania · Roofing Contractors · NAICS 238160
Since 2004, OSHA inspectors have visited R.A.M.E. Inc. in Pennsylvania 12 times.
The most recent inspection opened on Feb 20, 2026, in Homestead.
In all, OSHA issued 23 citation items: 14 serious, 2 repeat and 7 other-than-serious.
The proposed penalties came to $54,544; today they stand at $34,189, 37% less.
The rule cited most here is 1926.760 (fall protection), 4 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. R.A.M.E. Inc. averages $3,065 across 3 cited inspections.
Pennsylvania · latest 90 days of OSHA records
297employers cited
30 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch R.A.M.E. Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company220 East Oliver Road, Homestead, PA 15120 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1600 Metropolitan Drive, Washington, PA 15301 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1000 Ross Park Mall Drive, Pittsburgh, PA 15237 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.502(e)(1) · Fall protection systems |
Other-than-serious | $7,813 | $5,000 | Jun 14, 2023 | Final |
20133 Route 19, Cranberry Township, PA 16066 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5 Commercial Drive, Washington, PA 15301 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4750 Clairton Boulevard, Pittsburgh, PA 15238 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(4)(i) · Fall protection in construction |
Other-than-serious | $4,656 | $2,795 | Jul 10, 2018 | Final |
| Citation 2, item 1 29 CFR 1926.503(c) · Fall protection training in construction |
Other-than-serious | $0 | $0 | Jul 10, 2018 | Final |
2500 Smallman Street, Pittsburgh, PA 15222 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.502(b)(1) · Fall protection systems |
Other-than-serious | $2,800 | $1,400 | Aug 4, 2015 | Final |
625 Technology Drive, Coal Center, PA 15031 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.95(a) · Criteria for personal protective equipment |
Serious | $900 | $2,429 | Jan 22, 2007 | Closed |
| Citation 1, item 2a 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $900 | $2,429 | Jan 22, 2007 | Closed |
| Citation 1, item 2b 29 CFR 1926.405(a)(2)(iii) · Job-site wiring |
Serious | $0 | $0 | Jan 22, 2007 | Closed |
| Citation 1, item 3 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $2,000 | $2,429 | Jan 22, 2007 | Closed |
| Citation 1, item 4a 29 CFR 1926.454(c)(3) · Scaffold training |
Serious | $2,100 | $2,429 | Jan 22, 2007 | Closed |
| Citation 1, item 4b 29 CFR 1926.503(c) · Fall protection training in construction |
Serious | $0 | $0 | Jan 22, 2007 | Closed |
| Citation 1, item 5 29 CFR 1926.754(e)(2)(ii) · Structural steel assembly |
Serious | $3,000 | $2,429 | Jan 22, 2007 | Closed |
| Citation 1, item 6 29 CFR 1926.760(d)(2) · Fall protection |
Serious | $3,000 | $2,429 | Jan 22, 2007 | Closed |
| Citation 2, item 1 29 CFR 1926.760(a)(1) · Fall protection |
Repeat | $15,000 | $2,430 | Jan 22, 2007 | Closed |
2022 Mountain Road, Manheim, PA 17545 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.350(a)(9) · Gas welding and cutting |
Serious | $675 | $440 | Feb 23, 2005 | Closed |
| Citation 1, item 1b 29 CFR 1926.350(a)(10) · Gas welding and cutting |
Serious | $0 | $0 | Feb 23, 2005 | Closed |
2022 Mountain Road, Manheim, PA 17545 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $1,200 | $500 | Jan 20, 2005 | Closed |
| Citation 2, item 1 29 CFR 1926.760(a)(1) · Fall protection |
Repeat | $6,000 | $4,000 | Jan 20, 2005 | Closed |
Old Ppg Site, Ford City, PA 16226 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.760(a)(1) · Fall protection |
Serious | $3,000 | $2,000 | May 19, 2004 | Closed |
Seven Oaks Country Club, Beaver Falls, PA 15010 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $1,500 | $1,050 | Apr 15, 2004 | Closed |
| Citation 1, item 1b 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $0 | $0 | Apr 15, 2004 | Closed |
| Citation 2, item 1 29 CFR 1926.150(c)(1)(i) · Fire protection |
Other-than-serious | $0 | $0 | Apr 15, 2004 | Closed |
| Citation 2, item 2 29 CFR 1926.250(c) · General requirements for storage |
Other-than-serious | $0 | $0 | Apr 15, 2004 | Closed |
| Citation 2, item 3 29 CFR 1926.453(b)(2)(iv) · Aerial lifts |
Other-than-serious | $0 | $0 | Apr 15, 2004 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.150(c)(1)(i)
(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.
29 CFR 1926.250(c)
(c) Housekeeping. Storage areas shall be kept free from accumulation of materials that constitute hazards from tripping, fire, explosion, or pest harborage. Vegetation control will be exercised when necessary.
29 CFR 1926.350(a)(10)
(10) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.