OSHA SearchOSHA records by employer

R M Pacella Inc: OSHA inspections and violations

Beverly, Massachusetts · Site Preparation Contractors · NAICS 238910

10inspections
9citation items
$15,316current penalties
Jul 17, 2026last inspection

R M Pacella Inc has 10 OSHA inspections on record in Massachusetts, the first in 2000.

OSHA's last visit started on Jul 17, 2026 after a complaint, in Stoughton.

Across those inspections OSHA issued 9 citation items: 6 serious and 3 other-than-serious.

OSHA proposed $21,048 in penalties. After settlements and reviews the total is $15,316, down 27%.

Most often, OSHA cited 1926.1053, ladders in construction (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. R M Pacella Inc averages $6,220 over 2 cited inspections in that time.

R M Pacella Inc: OSHA citation items per year, 2000 to 2026
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

247employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch R M Pacella Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349114959 OPENED JUL 17, 2026Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Aug 26, 2026

Route 138, Stoughton, MA 02072 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 349057794 OPENED JUL 16, 2026Open

Inspection · Partial · Health · 50 employees at the site · Open

252 Washington Street, Attleboro, MA 02703 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1153(c)(1) · Silica dust in construction
Other-than-serious$8,441$8,441Oct 9, 2026Final
Citation 1, item 1b
29 CFR 1926.1153(g)(1) · Silica dust in construction
Other-than-serious$0$0Oct 9, 2026Final

Inspection 348741422 OPENED FEB 10, 2026Closed

Planned · Partial · Safety · 50 employees at the site · Closed Feb 19, 2026

Route 6 West Lane, Swansea, MA 02777 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348077538 OPENED FEB 26, 2025Closed

Planned · Partial · Safety · 50 employees at the site · Closed Mar 3, 2025

East St, Dedham, MA 02026 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348048711 OPENED FEB 12, 2025Closed

Complaint · No inspection · Safety · Closed Feb 19, 2025

, MA · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347907214 OPENED DEC 2, 2024Closed

Referral · Partial · Health · 3 employees at the site · Closed Apr 17, 2025

Granite St, Braintree, MA 02184 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$6,857$4,000Dec 3, 2024Final

Inspection 347907990 OPENED DEC 2, 2024Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Apr 2, 2025

Rotary At East And Cedar Streets, Dedham, MA 02026 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306095241 OPENED MAR 28, 2003Closed

Referral · Partial · Safety · 25 employees at the site · Closed Apr 1, 2003

Great Pond Road, North Andover, MA 01845 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

2 older inspections

Inspection 113546766 OPENED OCT 12, 2000Closed

Planned · Complete · Safety · 2 employees at the site · Closed Dec 5, 2000

Route 62, Greene Street, Beverly, MA 01915 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,000$1,000Oct 20, 2000Closed
Citation 1, item 2
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$600$300Oct 20, 2000Closed

Inspection 113546618 OPENED SEP 14, 2000Closed

Planned · Complete · Safety · 5 employees at the site · Closed Dec 22, 2000

Route 63, Beverly, MA 01915 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$600$300Oct 13, 2000Closed
Citation 1, item 2
29 CFR 1926.652(a)(1) · Trench protection
Serious$1,500$750Oct 13, 2000Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$600$300Oct 13, 2000Closed
Citation 1, item 4
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$450$225Oct 13, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1153 · Silica dust in construction

29 CFR 1926.20 · Construction safety programs