OSHA SearchOSHA records by employer

Rafael Ponce: OSHA inspections and violations

League City, Texas · Masonry Contractors · NAICS 238140

1inspections
3citation items
$1,020current penalties
Jun 22, 2016last inspection

Rafael Ponce has one OSHA inspection on record in Texas.

OSHA opened it on Jun 22, 2016 as a planned inspection, in League City.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $1,700 in penalties. After settlements and reviews the total is $1,020, down 40%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Rafael Ponce averages $1,020 over 1 cited inspection in that time.

Rafael Ponce: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Rafael Ponce again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341575132 OPENED JUN 22, 2016Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 30, 2017

1541 Nacodoches Valley Dr, League City, TX 77573 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,700$1,020Jul 19, 2016Final
Citation 1, item 1b
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0Jul 19, 2016Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jul 19, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(i)

(i) Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

Other masonry contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.