OSHA SearchOSHA records by employer

RCK LLC: OSHA inspections and violations

Sanford, Florida · Electromedical and Electrotherapeutic Apparatus Manufacturing · NAICS 334510

1inspections
6citation items
$12,314current penalties
Dec 15, 2016last inspection

OSHA inspectors have visited RCK LLC in Florida one time.

It opened on Dec 15, 2016 after a complaint, in Sanford.

In all, OSHA issued 6 citation items: 6 serious.

The penalties, $12,314 in total, stand where OSHA first set them.

The rule cited most here is 1910.1025 (lead in general industry), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. RCK LLC averages $12,314 across 1 cited inspection.

RCK LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites RCK LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341983724 OPENED DEC 15, 2016Closed

Complaint · Partial · Health · 24 employees at the site · Closed Apr 16, 2018

2647 N. Design Court, Sanford, FL 32773 · Electromedical and Electrotherapeutic Apparatus Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(2) · Machine guarding
Serious$5,070$5,070May 5, 2017Final
Citation 1, item 2
29 CFR 1910.305(d)(2) · Electrical wiring methods
Serious$3,622$3,622May 5, 2017Final
Citation 1, item 3a
29 CFR 1910.1025(d)(2) · Lead in general industry
Serious$3,622$3,622May 5, 2017Final
Citation 1, item 3b
29 CFR 1910.1025(h)(1) · Lead in general industry
Serious$0$0May 5, 2017Final
Citation 1, item 3c
29 CFR 1910.1025(m)(1)(i) · Lead in general industry
Serious$0$0May 5, 2017Final
Citation 1, item 3d
29 CFR 1910.1025(l)(1)(ii) · Lead in general industry
Serious$0$0May 5, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1025 · Lead in general industry

29 CFR 1910.1025(d)(2)

(2) Initial determination. Each employer who has a workplace or work operation covered by this standard shall determine if any exployee may be exposed to lead at or above the action level.

29 CFR 1910.1025(h)(1)

(h) Housekeeping—(1) Surfaces. All surfaces shall be maintained as free as practicable of accumulations of lead.

29 CFR 1910.1025(l)(1)(ii)

(ii) The employer shall train each employee who is subject to exposure to lead at or above the action level, or for whom the possibility of skin or eye irritation exists, in accordance with the requirements of this section. The employer shall institute a training program and ensure employee participation in the program.

29 CFR 1910.212 · Machine guarding