OSHA SearchOSHA records by employer

Ream Roofing Associates, LLC: OSHA inspections and violations

Baltimore, Maryland · Roofing Contractors · NAICS 238160

5inspections
16citation items
$1,700current penalties
Dec 20, 2022last inspection

Ream Roofing Associates, LLC has 5 OSHA inspections on record in Maryland, the first in 1997.

OSHA's last visit started on Dec 20, 2022 as a planned inspection, in Williamsport.

Across those inspections OSHA issued 16 citation items: 8 serious and 8 other-than-serious.

OSHA proposed $2,849 in penalties. After settlements and reviews the total is $1,700, down 40%.

Most often, OSHA cited 1926.501, fall protection in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Ream Roofing Associates, LLC averages $212 over 2 cited inspections in that time.

Ream Roofing Associates, LLC: OSHA citation items per year, 1997 to 2022
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

189employers cited

35 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Ream Roofing Associates, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346405160 OPENED DEC 20, 2022Closed

Planned · Complete · Safety · 3 employees at the site · Closed Mar 16, 2023

17250 Sterling Road, Williamsport, MD 21795 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$787$425Feb 27, 2023Final
Citation 2, item 1
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Feb 27, 2023Final
Citation 2, item 2
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Feb 27, 2023Final

Inspection 342884509 OPENED JAN 11, 2018Closed

Planned · Complete · Safety · 5 employees at the site · Closed Apr 12, 2018

201 N. Schroeder Street, Baltimore, MD 21205 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(a)(4) · Fire protection
Other-than-serious$0$0Apr 5, 2018Final
Citation 1, item 2
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$0$0Apr 5, 2018Final
Citation 1, item 3
29 CFR 1926.502(i)(4) · Fall protection systems
Other-than-serious$0$0Apr 5, 2018Final

Inspection 342676921 OPENED OCT 2, 2017Closed

Planned · Complete · Safety · 6 employees at the site · Closed Oct 10, 2017

20 East Lanvale Street, Baltimore, MD 21202 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339863060 OPENED JUL 18, 2014Closed

Planned · Complete · Safety · 5 employees at the site · Closed Nov 3, 2014

2 Wells Street, Baltimore, MD 21230 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(d)(1) · Electrical equipment on job sites
Other-than-serious$0$0Aug 4, 2014Final

Inspection 119591832 OPENED JUN 4, 1997Closed

Planned · Complete · Safety · 8 employees at the site · Closed Feb 9, 1998

Freedom Village Shopping Ctr 6300 Georgetown Blvd, Eldersburg, MD 21784 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.252(a) · Disposal of waste materials
Serious$750$375Jul 11, 1997Closed
Citation 2, item 1a
29 CFR 1926.501(b)(3) · Fall protection in construction
Serious$875$600Jul 11, 1997Closed
Citation 2, item 1b
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$0$0Jul 11, 1997Closed
Citation 2, item 1c
29 CFR 1926.502(h)(1) · Fall protection systems
Serious$0$0Jul 11, 1997Closed
Citation 2, item 1d
29 CFR 1926.502(j)(7)(i) · Fall protection systems
Serious$0$0Jul 11, 1997Closed
Citation 3, item 1a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$437$300Jul 11, 1997Closed
Citation 3, item 1b
29 CFR 1926.1053(b)(8) · Ladders in construction
Serious$0$0Jul 11, 1997Closed
Citation 4, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$0$0Jul 11, 1997Closed
Citation 4, item 2
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Jul 11, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.150 · Fire protection

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.252 · Disposal of waste materials

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.