OSHA SearchOSHA records by employer

Regal Air, Inc.: OSHA inspections and violations

Cheyenne, Wyoming · Other Support Activities for Air Transportation · NAICS 488190

1inspections
6citation items
$9,313current penalties
Jul 19, 2018last inspection

OSHA inspectors have visited Regal Air, Inc. in Wyoming one time.

It opened on Jul 19, 2018 after a complaint, in Cheyenne.

In all, OSHA issued 6 citation items: 4 serious and 2 other-than-serious.

The proposed penalties came to $11,088; today they stand at $9,313, 16% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among transportation and warehousing employers, the typical cited inspection since 2015 ends with a $2,416 penalty. Regal Air, Inc. averages $9,313 across 1 cited inspection.

Regal Air, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Wyoming · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wyoming

Checking a subcontractor, a client or your own company? Watch Regal Air, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343549937 OPENED JUL 19, 2018Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Apr 1, 2019

1400 W. 24th, Cheyenne, WY 82001 · Other Support Activities for Air Transportation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.176(b) · Material storage and aisles
Serious$3,696$3,326Dec 17, 2018Final
Citation 1, item 2
29 CFR 1910.305(a)(2)(xi) · Electrical wiring methods
Serious$3,696$2,661Dec 17, 2018Final
Citation 1, item 3a
29 CFR 1910.305(b)(3)(ii) · Electrical wiring methods
Serious$3,696$3,326Dec 17, 2018Final
Citation 1, item 3b Serious$0$0Dec 17, 2018Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 17, 2018Final
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 17, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.176(b)

(b) Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.332 · Training

Other other support activities for air transportation employers in Wyoming

Alert subscribers get notified of each newly cited employer in Wyoming the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.