OSHA SearchOSHA records by employer

Rensselaer Co Sewer Dist WWTP: OSHA inspections and violations

Troy, New York · Sewage Treatment Facilities · NAICS 221320

8inspections
19citation items
$0current penalties
Apr 26, 2024last inspection

Since 2015, OSHA inspectors have visited Rensselaer Co Sewer Dist WWTP in New York 8 times.

The most recent inspection opened on Apr 26, 2024 to follow up on an earlier case, in Troy.

In all, OSHA issued 19 citation items: 18 serious and 1 other-than-serious.

No penalty came with these citations.

The rule cited most here is 1910.23 (ladders in general industry), 3 times.

Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Rensselaer Co Sewer Dist WWTP averages $0 across 2 cited inspections.

Rensselaer Co Sewer Dist WWTP: OSHA citation items per year, 2015 to 2024
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

376employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Rensselaer Co Sewer Dist WWTP and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347445231 OPENED APR 26, 2024Closed

Follow-up · Partial · Health · Local government · 32 employees at the site · Closed May 3, 2024

Foot Of Water St, Troy, NY 12180 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346335441 OPENED NOV 9, 2022Closed

Follow-up · Partial · Safety · Local government · 35 employees at the site · Closed Nov 18, 2022

Foot Of Water St, Troy, NY 12180 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346303431 OPENED OCT 25, 2022Closed

Monitoring · Partial · Safety · Local government · 35 employees at the site · Closed Nov 18, 2022

Foot Of Water St, Troy, NY 12180 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345701395 OPENED DEC 23, 2021Closed

Complaint · Partial · Health · Local government · 32 employees at the site · Closed May 3, 2024

Foot Of Water St, Troy, NY 12180 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Serious$0$0Jan 17, 2024Final
Citation 1, item 2
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$0$0Jan 17, 2024Final
Citation 1, item 3
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jan 17, 2024Final

Inspection 345539480 OPENED SEP 21, 2021Closed

Monitoring · Partial · Safety · Local government · 35 employees at the site · Closed Sep 28, 2021

Foot Of Water Street, Troy, NY 12180 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344228739 OPENED AUG 13, 2019Closed

Planned · Complete · Safety · Local government · 35 employees at the site · Closed Nov 18, 2022

Foot Of Water Street, Troy, NY 12180 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(1) · Walking-working surfaces
Serious$0$0Jan 15, 2020Final
Citation 1, item 2
29 CFR 1910.23(a)(8)(ii) · Ladders in general industry
Serious$0$0Jan 15, 2020Final
Citation 1, item 3
29 CFR 1910.23(c)(1) · Ladders in general industry
Serious$0$0Jan 15, 2020Final
Citation 1, item 4
29 CFR 1910.23(c)(3) · Ladders in general industry
Serious$0$0Jan 15, 2020Final
Citation 1, item 5
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Jan 15, 2020Final
Citation 1, item 6
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jan 15, 2020Final
Citation 1, item 7
29 CFR 1910.269(a)(2)(i)(a) · Electric power generation, transmission, and distribution
Serious$0$0Jan 15, 2020Final
Citation 1, item 8
29 CFR 1910.269(l)(8)(ii) · Electric power generation, transmission, and distribution
Serious$0$0Jan 15, 2020Final
Citation 1, item 9
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Jan 15, 2020Final
Citation 1, item 10
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$0$0Jan 15, 2020Final
Citation 1, item 11
29 CFR 1910.304(b)(3)(i) · Grounding and circuit protection
Serious$0$0Jan 15, 2020Final
Citation 1, item 12
29 CFR 1910.305(j)(2)(vii) · Electrical wiring methods
Serious$0$0Jan 15, 2020Final
Citation 1, item 13 Serious$0$0Jan 15, 2020Final
Citation 1, item 14
29 CFR 1910.333(b)(2)(i) · Working near live electrical parts
Serious$0$0Jan 15, 2020Final
Citation 1, item 15
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Jan 15, 2020Final
Citation 2, item 1
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Jan 15, 2020Final

Inspection 342922762 OPENED FEB 2, 2018Closed

Complaint · Partial · Health · Local government · 33 employees at the site · Closed Apr 9, 2018

Water Street, Troy, NY 12180 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340559152 OPENED APR 15, 2015Closed

Complaint · Partial · Health · Local government · 33 employees at the site · Closed Jun 24, 2015

Water Street, Troy, NY 12180 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.1200(g)(8)

(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.332 · Training

29 CFR 1910.333 · Working near live electrical parts

Other sewage treatment facilities employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.