OSHA SearchOSHA records by employer

Revolution Erecting LLC: OSHA inspections and violations

Naples, Florida · Structural Steel and Precast Concrete Contractors · NAICS 238120

1inspections
2citation items
$8,096current penalties
Jul 13, 2020last inspection

OSHA inspectors have visited Revolution Erecting LLC in Florida one time.

It opened on Jul 13, 2020 on a referral, in Naples.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $8,096 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Revolution Erecting LLC averages $8,096 across 1 cited inspection.

It reported 1 severe injury to OSHA since 2015.

Revolution Erecting LLC: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Revolution Erecting LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344829585 OPENED JUL 13, 2020Closed

Referral · Partial · Safety · 2 employees at the site · Closed Apr 13, 2023

1 Sabre Lane, Naples, FL 34102 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jul 11, 2020: One employee sustains concussion, crush injuries and other s

At 4:00 p.m. on July 11, 2020, Employee #1 (owner) and Employee #2 (brother of the owner) were working as carpenters for a building contractor subcontracted to install a floor slab. The employees were standing on top of hollow-core concrete floor panels on the 2nd floor of a newly constructed residence. The employees were fabricating and installing hollow core slabs. The panels collapsed onto the lower floor as a result of the failure of the fasteners that secured the brackets to the wall. The employees fell when the slabs no longer were supported by the angle clips on the tie-beams. A pallet of cement bags had been stored on top of the hollow core panels. The employees were using self-retractable lifelines attached to an anchor in the core slab. However, they removed the lifeline to place cement between the slab joints and were not working at the edge at any time after they removed their lifeline. The debris from the hollow core pinned Employee #1, who was hospitalized to treat a concussion and multiple crushing injuries. Employee #2 received treatment without hospitalization for minor injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.701(a) · Concrete and Masonry Construction: general requirements
Serious$4,048$4,048Jan 11, 2021Final
Citation 1, item 2
29 CFR 1926.704(a) · Requirements for precast concrete
Serious$4,048$4,048Jan 11, 2021Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jul 11, 2020, Naples: Hospitalization · traumatic injuries and disorders, unspecified · nonclassifiable

Two employees were installing pre-cast concrete floor panels. The concrete floor panels collapsed onto the lower floor when the brackets and/or screws that secured the brackets into the wall failed. Both employees were hospitalized with blunt force trauma injuries.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.701(a)

(a) Construction loads. No construction loads shall be placed on a concrete structure or portion of a concrete structure unless the employer determines, based on information received from a person who is qualified in structural design, that the structure or portion of the structure is capable of supporting the loads.

29 CFR 1926.704 · Requirements for precast concrete

29 CFR 1926.704(a)

(a) Precast concrete wall units, structural framing, and tilt-up wall panels shall be adequately supported to prevent overturning and to prevent collapse until permanent connections are completed.

Other structural steel and precast concrete contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.