OSHA SearchOSHA records by employer

Rick Construction Co Inc: OSHA inspections and violations

Carmel, Indiana · Tile and Terrazzo Contractors · NAICS 238340

3inspections
28citation items
$5,188current penalties
Jun 20, 2016last inspection

Rick Construction Co Inc has 3 OSHA inspections on record in Indiana, the first in 1986.

OSHA's last visit started on Jun 20, 2016 on a referral, in Nora.

Across those inspections OSHA issued 28 citation items: 14 serious and 14 other-than-serious.

OSHA proposed $8,370 in penalties. After settlements and reviews the total is $5,188, down 38%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Rick Construction Co Inc averages $4,093 over 1 cited inspection in that time.

Rick Construction Co Inc: OSHA citation items per year, 1986 to 2016
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

78employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Rick Construction Co Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341565307 OPENED JUN 20, 2016Closed

Referral · Partial · Safety · 5 employees at the site · Closed Aug 23, 2016

4397 West 86th Street, Nora, IN 46260 · Tile and Terrazzo Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$450$292Jul 18, 2016Final
Citation 1, item 2
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$450$292Jul 18, 2016Final
Citation 1, item 3
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$450$292Jul 18, 2016Final
Citation 1, item 4
29 CFR 1926.100(a) · Hard hats in construction
Serious$450$292Jul 18, 2016Final
Citation 1, item 5
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$1,500$975Jul 18, 2016Final
Citation 1, item 6
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,500$975Jul 18, 2016Final
Citation 1, item 7
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,500$975Jul 18, 2016Final

Inspection 108609470 OPENED SEP 29, 1992Closed

Planned · Complete · Safety · 3 employees at the site · Closed Dec 28, 1992

(dunkin Donuts) 1610 E Michigan Road, Shelbyville, IN 46176 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Serious$450$225Nov 6, 1992Closed
Citation 1, item 2
29 CFR 1926.59(g)(1) · Hazard communication
Serious$450$225Nov 6, 1992Closed
Citation 1, item 3
29 CFR 1926.59(h) · Hazard communication
Serious$450$225Nov 6, 1992Closed
Citation 1, item 4
29 CFR 1926.100(a) · Hard hats in construction
Serious$600$300Nov 6, 1992Closed
Citation 2, item 1
29 CFR 1926.50(c) · Medical services and first aid
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 2
29 CFR 1926.50(d)(1) · Medical services and first aid
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 3
29 CFR 1926.50(f) · Medical services and first aid
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 4
29 CFR 1926.59(e)(1)(i) · Hazard communication
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 5
29 CFR 1926.150(a)(1) · Fire protection
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 6
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 7
29 CFR 1926.403(g) · Electrical equipment on job sites
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 8
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 9
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 10
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 11
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 12
29 CFR 1926.451(a)(12) · Scaffolds, general requirements
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 13
29 CFR 1926.451(a)(14) · Scaffolds, general requirements
Other-than-serious$0$0Nov 6, 1992Closed
Citation 2, item 14
29 CFR 1926.451(d)(3) · Scaffolds, general requirements
Other-than-serious$0$0Nov 6, 1992Closed

Inspection 101952372 OPENED MAR 20, 1986Closed

Planned · Complete · Safety · 3 employees at the site · Closed Apr 23, 1987

Restaurant-1331 S. Rangeline Rd., Carmel, IN 46032 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.400(h)(1) · Introduction
Serious$60$60Apr 3, 1986Closed
Citation 1, item 2a
29 CFR 1926.450(a)(9) · Scope, application and definitions applicable to this subpart
Serious$60$60Apr 3, 1986Closed
Citation 1, item 2b
29 CFR 1926.450(a)(10) · Scope, application and definitions applicable to this subpart
Serious$0$0Apr 3, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(a)(1)

(a) General requirements. (1) The employer shall be responsible for the development of a fire protection program to be followed throughout all phases of the construction and demolition work, and he shall provide for the firefighting equipment as specified in this subpart. As fire hazards occur, there shall be no delay in providing the necessary equipment.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(a)(1)

(a) General requirements. (1) Only approved containers and portable tanks shall be used for storage and handling of flammable liquids. Approved safety cans or Department of Transportation approved containers shall be used for the handling and use of flammable liquids in quantities of 5 gallons or less, except that this shall not apply to those flammable liquid materials which are highly viscid (extremely hard to pour), which may be used and handled in original shipping containers. For quantities of one gallon or less, the original container may be used, for storage, use and handling of flammable liquids.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.400 · Introduction

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.59 · Hazard communication

29 CFR 1926.95 · Criteria for personal protective equipment

Other tile and terrazzo contractors employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.