OSHA SearchOSHA records by employer

Rick's Auto Body, Inc.: OSHA inspections and violations

Missoula, Montana · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

4inspections
13citation items
$39,381current penalties
Feb 12, 2026last inspection

Since 2013, OSHA inspectors have visited Rick's Auto Body, Inc. in Montana 4 times.

The most recent inspection opened on Feb 12, 2026 as a planned inspection, in Missoula.

In all, OSHA issued 13 citation items: 10 serious and 3 other-than-serious.

The proposed penalties came to $57,862; today they stand at $39,381, 32% less.

The rule cited most here is 1910.106 (flammable liquids), 6 times.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. Rick's Auto Body, Inc. averages $3,381 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Rick's Auto Body, Inc.: OSHA citation items per year, 2013 to 2026
Citation items per year, by inspection date.

Montana · latest 90 days of OSHA records

29employers cited

Get notified the morning OSHA posts each new citation in Montana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Montana

Checking a subcontractor, a client or your own company? Watch Rick's Auto Body, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348749417 OPENED FEB 12, 2026Closed

Planned · Partial · Safety · 30 employees at the site · Closed May 5, 2026

2008 W Broadway, Missoula, MT 59808 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343590915 OPENED NOV 6, 2018Closed

Planned · Complete · Safety · 35 employees at the site · Closed Mar 8, 2019

2008 W Broadway, Missoula, MT 59808 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$3,381$1,690Jan 28, 2019Final
Citation 1, item 2a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$3,381$1,690Jan 28, 2019Final
Citation 1, item 2b
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 28, 2019Final

Inspection 343591004 OPENED NOV 6, 2018Closed

Planned · Complete · Health · 35 employees at the site · Closed Dec 7, 2018

2008 W Broadway, Missoula, MT 59808 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339341638 OPENED AUG 21, 2013Closed

Fatality or catastrophe · Complete · Safety · 35 employees at the site · Closed May 28, 2014

2008 West Broadway, Missoula, MT 59808 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Incident on Aug 19, 2013 (fatal): Employee dies after solvent ignites in an auto body shop

At 10:00 a.m. on August 19, 2013, an employee was working for an auto body shop. He was transferring flammable solvent liquid from a plastic 18.9-liter (5-gallon) bucket into a plastic 208.2 (55-gallon0 drum via a metal funnel. The flammable vapors ignited, probably from static electricity. The employee sustained third-degree burns to 95 percent of his body. He was hospitalized, and he died. Other workers were also involved. The file said that two workers were not hospitalized and that two workers were hospitalized. The employee who died might have been one of the hospitalized workers.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$2,800$500Nov 20, 2013Final
Citation 1, item 2
29 CFR 1910.37(b)(2) · Exit routes
Serious$3,500$2,500Nov 20, 2013Final
Citation 1, item 3a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$4,900$2,500Nov 20, 2013Final
Citation 1, item 4
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$7,000$7,000Nov 20, 2013Final
Citation 1, item 6a
29 CFR 1910.106(e)(2)(ii) · Flammable liquids
Serious$7,000$7,000Nov 20, 2013Final
Citation 1, item 6b
29 CFR 1910.106(e)(2)(iv)(d) · Flammable liquids
Serious$7,000$0Nov 20, 2013Final
Citation 1, item 7
29 CFR 1910.106(e)(5)(iv) · Flammable liquids
Serious$7,000$7,000Nov 20, 2013Final
Citation 1, item 8
29 CFR 1910.107(c)(9)(i) · Spray painting and finishing
Serious$4,900$2,500Nov 20, 2013Final
Citation 1, item 9a
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$7,000$7,000Nov 20, 2013Final
Citation 1, item 9b
29 CFR 1910.107(e)(9) · Spray painting and finishing
Serious$0$0Nov 20, 2013Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(e)(2)(ii)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.37 · Exit routes

Other automotive body, paint, and interior repair and maintenance employers in Montana

Alert subscribers get notified of each newly cited employer in Montana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.