OSHA SearchOSHA records by employer

Riverbank Building Supply , Inc.: OSHA inspections and violations

Williamston, North Carolina · Other Building Material Dealers · NAICS 444190

2inspections
14citation items
$1,375current penalties
Mar 28, 2018last inspection

Since 2009, OSHA inspectors have visited Riverbank Building Supply , Inc. in North Carolina 2 times.

The most recent inspection opened on Mar 28, 2018 as a planned inspection, in Williamston.

In all, OSHA issued 14 citation items: 9 serious and 5 other-than-serious.

The proposed penalties came to $1,475; today they stand at $1,375, 7% less.

The rule cited most here is 1910.305 (electrical wiring methods), 3 times.

Among retail employers, the typical cited inspection since 2015 ends with a $1,750 penalty. Riverbank Building Supply , Inc. averages $600 across 1 cited inspection.

Riverbank Building Supply , Inc.: OSHA citation items per year, 2009 to 2018
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Riverbank Building Supply , Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343056859 OPENED MAR 28, 2018Closed

Planned · Complete · Safety · 11 employees at the site · Closed Jul 24, 2018

620 E Main Street, Williamston, NC 27892 · Home Centers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Serious$300$300May 23, 2018Final
Citation 1, item 1b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0May 23, 2018Final
Citation 1, item 2
29 CFR 1910.178(l)(2)(ii) · Forklifts and other powered industrial trucks
Serious$300$300May 23, 2018Final
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0May 23, 2018Final
Citation 2, item 2
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0May 23, 2018Final

Inspection 312880693 OPENED APR 23, 2009Closed

Planned · Complete · Safety · 9 employees at the site · Closed Aug 19, 2009

620 East Main Street, Williamston, NC 27892 · Other Building Material Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Serious$250$250May 8, 2009Closed
Citation 1, item 1b
29 CFR 1910.23(d)(1)(i) · Guarding floor and wall openings and holes
Serious$0$0May 8, 2009Closed
Citation 1, item 1c
29 CFR 1910.23(d)(1)(iv) · Guarding floor and wall openings and holes
Serious$0$0May 8, 2009Closed
Citation 1, item 2
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$350$350May 8, 2009Closed
Citation 1, item 3a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$175$175May 8, 2009Closed
Citation 1, item 3b
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$0$0May 8, 2009Closed
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$100$0May 8, 2009Closed
Citation 2, item 2
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0May 8, 2009Closed
Citation 2, item 3
29 CFR 1910.305(g)(1)(iva) · Electrical wiring methods
Other-than-serious$0$0May 8, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.133(a)(1)

(a) General requirements. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other other building material dealers employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.