OSHA SearchOSHA records by employer

RJF Morin Brick, LLC.: OSHA inspections and violations

Auburn, Maine · Concrete Block and Brick Manufacturing · NAICS 327331

3inspections
19citation items
$22,012current penalties
Sep 16, 2020last inspection

OSHA has inspected RJF Morin Brick, LLC. 3 times in Maine since 2011.

The latest one began on Sep 16, 2020 on a referral, in Auburn.

Those inspections ended with 19 citation items: 15 serious and 4 other-than-serious.

Penalties were first proposed at $40,246 and now stand at $22,012, 45% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 5 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and RJF Morin Brick, LLC. averages $3,306 (2 cited inspections).

It reported 2 severe injuries to OSHA since 2015.

RJF Morin Brick, LLC.: OSHA citation items per year, 2011 to 2020
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

34employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch RJF Morin Brick, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344929153 OPENED SEP 16, 2020Closed

Referral · Partial · Safety · 50 employees at the site · Closed Dec 23, 2020

130 Morin Brick Rd, Auburn, ME 04211 · Concrete Block and Brick Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Sep 4, 2020: Employee amputates fingertip in pinch point

At 8:00 a.m. on September 4, 2020, an employee was cleaning the floor area. The employee lifted a guard and placed his hand in near the chain and sprocket to try and clean the chain. The employee amputated a fingertip at the pinch point and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$9,446$6,612Dec 4, 2020Final

Inspection 341412732 OPENED APR 20, 2016Closed

Complaint · Partial · Health · 48 employees at the site · Closed Jun 2, 2016

130 Morin Brick Road, Auburn, ME 04210 · Concrete Block and Brick Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0May 5, 2016Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0May 5, 2016Final

Inspection 315635458 OPENED JUN 15, 2011Closed

Planned · Complete · Safety · 52 employees at the site · Closed Aug 1, 2011

130 Morin Brick Road, Auburn, ME 04211 · Clay Building Material and Refractories Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$3,500$1,750Jul 8, 2011Closed
Citation 1, item 2
29 CFR 1910.27(d)(3) · Fixed ladders
Serious$2,800$1,400Jul 8, 2011Closed
Citation 1, item 3a
29 CFR 1910.147(d)(3) · Lockout/tagout
Serious$4,900$2,450Jul 8, 2011Closed
Citation 1, item 3b
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$0$0Jul 8, 2011Closed
Citation 1, item 3c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Jul 8, 2011Closed
Citation 1, item 3d
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Jul 8, 2011Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,500$1,750Jul 8, 2011Closed
Citation 1, item 5
29 CFR 1910.212(a)(2) · Machine guarding
Serious$2,100$1,050Jul 8, 2011Closed
Citation 1, item 6
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$3,500$1,750Jul 8, 2011Closed
Citation 1, item 7
29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts
Serious$4,900$2,450Jul 8, 2011Closed
Citation 1, item 8
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Serious$2,100$1,050Jul 8, 2011Closed
Citation 1, item 9a
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$3,500$1,750Jul 8, 2011Closed
Citation 1, item 9b Serious$0$0Jul 8, 2011Closed
Citation 1, item 9c
29 CFR 1910.333(b)(2)(i) · Working near live electrical parts
Serious$0$0Jul 8, 2011Closed
Citation 2, item 1
29 CFR 1910.147(c)(5)(ii) · Lockout/tagout
Other-than-serious$0$0Jul 8, 2011Closed
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jul 8, 2011Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Nov 4, 2021, Auburn: Amputation · amputations · fingertip(s)

An employee was checking the airflow of a machine. His finger contacted a spinning fan blade, which amputated the fingertip.

Sep 4, 2020, Auburn: Amputation · amputations · finger(s), fingernail(s), unspecified

An employee was cleaning a brick machine when their glove was caught in a chain/sprocket assembly. A finger was partially amputated.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(5)(ii)

(ii) Lockout devices and tagout devices shall be singularly identified; shall be the only devices(s) used for controlling energy; shall not be used for other purposes; and shall meet the following requirements:

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.27 · Fixed ladders

29 CFR 1910.332 · Training

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.335 · Safeguards for personnel protection

Other concrete block and brick manufacturing employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.