OSHA SearchOSHA records by employer

Roadrunner Plaster & Drywall: OSHA inspections and violations

Santa Fe, New Mexico · Drywall and Insulation Contractors · NAICS 238310

1inspections
3citation items
$600current penalties
Jan 22, 2016last inspection

Roadrunner Plaster & Drywall has one OSHA inspection on record in New Mexico.

OSHA opened it on Jan 22, 2016 as part of a related case, in Santa Fe.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $600 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.452, rules for each type of scaffold (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Roadrunner Plaster & Drywall averages $600 over 1 cited inspection in that time.

Roadrunner Plaster & Drywall: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

New Mexico · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in New Mexico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Mexico

Checking a subcontractor, a client or your own company? Watch Roadrunner Plaster & Drywall and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341234094 OPENED JAN 22, 2016Closed

Unprogrammed related · Complete · Safety · 12 employees at the site · Closed Jul 19, 2016

4250 Cerrillos Rd, Santa Fe, NM 87501 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$300$300Apr 18, 2016Final
Citation 1, item 1b
29 CFR 1926.452(c)(4) · Rules for each type of scaffold
Serious$0$0Apr 18, 2016Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$300$300Apr 18, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(c)(2)

(2) Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured.

29 CFR 1926.452(c)(4)

(4) Where uplift can occur which would displace scaffold end frames or panels, the frames or panels shall be locked together vertically by pins or equivalent means.

Other drywall and insulation contractors employers in New Mexico

Alert subscribers get notified of each newly cited employer in New Mexico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.