Inspection 340732783 OPENED JUN 25, 2015Closed
2 Cairn Street, Rochester, NY 14611 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2010, OSHA inspectors have visited Rochester Overnight Plating LLC in New York 3 times.
The most recent inspection opened on Jun 25, 2015 on a referral, in Rochester.
In all, OSHA issued 12 citation items: 10 serious, 1 repeat and 1 other-than-serious.
The proposed penalties came to $24,458; today they stand at $15,508, 37% less.
The rule cited most here is 1910.335 (safeguards for personnel protection), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Rochester Overnight Plating LLC averages $8,500 across 1 cited inspection.
It reported 1 severe injury to OSHA since 2015.
New York · latest 90 days of OSHA records
358employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Rochester Overnight Plating LLC and get notified the morning OSHA posts a new citation for it.
Watch this company2 Cairn Street, Rochester, NY 14611 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2 Carin Street, Rochester, NY 14611 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $2,023 | $1,648 | Feb 20, 2015 | Final |
| Citation 1, item 2a 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $2,800 | $2,352 | Feb 20, 2015 | Final |
| Citation 1, item 2b 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Serious | $0 | $0 | Feb 20, 2015 | Final |
| Citation 1, item 3a 29 CFR 1910.304(a)(2) · Grounding and circuit protection |
Serious | $3,500 | $2,500 | Feb 20, 2015 | Final |
| Citation 1, item 3b 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Serious | $0 | $0 | Feb 20, 2015 | Final |
| Citation 2, item 1 29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection |
Repeat | $8,400 | $2,000 | Feb 20, 2015 | Final |
| Citation 3, item 1 29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Feb 20, 2015 | Final |
2 Carin Street, Rochester, NY 14611 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $2,975 | $2,000 | Jan 14, 2011 | Closed |
| Citation 1, item 2 29 CFR 1910.124(h)(4) · General requirements for dipping and coating operations |
Serious | $1,785 | $1,000 | Jan 14, 2011 | Closed |
| Citation 1, item 3 29 CFR 1910.333(c)(2) · Working near live electrical parts |
Serious | $2,975 | $2,000 | Jan 14, 2011 | Closed |
| Citation 1, item 6a 29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection |
Serious | $0 | $2,008 | Jan 14, 2011 | Closed |
| Citation 1, item 6b 29 CFR 1910.335(a)(2)(ia) · Safeguards for personnel protection |
Serious | $0 | $0 | Jan 14, 2011 | Closed |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Jun 20, 2015, Rochester: Hospitalization · chemical burns and corrosions, unspecified · multiple body parts, n.e.c.
An employee was changing a chemical in a cleaning tank on a plating line when the tank exploded. The chemical, Sirprep 309EC, is an electrical cleaner; it contacted the employee, and he suffered serious chemical burns on 20 percent of his body.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.124(h)(4)
(4) For employees who work with chromic acid, periodic examinations of their exposed body parts, especially their nostrils.
29 CFR 1910.151(c)
(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.
29 CFR 1910.179(g)(1)(v)
(v) Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.