OSHA SearchOSHA records by employer

Rogers Roofing: OSHA inspections and violations

Hammond, Indiana · Roofing Contractors · NAICS 238160

7inspections
10citation items
$14,600current penalties
Jan 3, 2025last inspection

Rogers Roofing has 7 OSHA inspections on record in Indiana, the first in 2015.

OSHA's last visit started on Jan 3, 2025 after a complaint, in Crown Point.

Across those inspections OSHA issued 10 citation items: 7 serious and 3 repeat.

OSHA proposed $19,750 in penalties. After settlements and reviews the total is $14,600, down 26%.

Most often, OSHA cited 1926.501, fall protection in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Rogers Roofing averages $3,650 over 4 cited inspections in that time.

Rogers Roofing also files yearly injury logs with OSHA, summarized below.

Rogers Roofing: OSHA citation items per year, 2015 to 2025
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

75employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Rogers Roofing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347965311 OPENED JAN 3, 2025Closed

Complaint · No inspection · Safety · 1 employee at the site · Closed May 8, 2025

10828 Park St Unit B, Crown Point, IN 46307 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346163694 OPENED AUG 22, 2022Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Nov 11, 2022

7020 Grand Ave, Hammond, IN 46323 · Roofing, Siding, and Insulation Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343360749 OPENED AUG 6, 2018Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Oct 29, 2018

620 Ridge Road, Munster, IN 46321 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342296852 OPENED APR 19, 2017Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Oct 6, 2017

730 45th Street, Munster, IN 46321 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$4,000$2,000Aug 7, 2017Final

Inspection 341205763 OPENED JAN 20, 2016Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Mar 27, 2017

7701 Us-41, Schererville, IN 46375 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Repeat$1,800$1,350Feb 23, 2016Final
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$6,000$4,500Feb 23, 2016Final

Inspection 341271146 OPENED JAN 15, 2016Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Apr 11, 2017

7700 Cabela Dr., Hammond, IN 46324 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$3,000$2,250Mar 4, 2016Final
Citation 2, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Repeat$1,800$1,350Mar 4, 2016Final

Inspection 340972991 OPENED OCT 1, 2015Closed

Complaint · Partial · Safety · 10 employees at the site · Closed Dec 22, 2015

Tech Credit Union 10951 Broadway Avenue, Southport, IN 46237 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$875$875Nov 25, 2015Final
Citation 1, item 2
29 CFR 1926.100(a) · Hard hats in construction
Serious$700$700Nov 25, 2015Final
Citation 1, item 3a
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$875$875Nov 25, 2015Final
Citation 1, item 3b
29 CFR 1926.502(f)(1) · Fall protection systems
Serious$0$0Nov 25, 2015Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$700$700Nov 25, 2015Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Hammond site logged 0 recordable injuries or illnesses among about 43 workers: 0.0 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Rogers Roofing
Hammond · 2024
43 000.02.8
Rogers Roofing, Inc
Hammond · 2023
35 000.02.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other roofing contractors employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.