OSHA SearchOSHA records by employer

Roma Steel Erection Inc.: OSHA inspections and violations

Philadelphia, Pennsylvania · Structural Steel and Precast Concrete Contractors · NAICS 238120

10inspections
17citation items
$13,109current penalties
Aug 3, 2023last inspection

OSHA has inspected Roma Steel Erection Inc. 10 times in Pennsylvania since 1987.

The latest one began on Aug 3, 2023 as a planned inspection, in Philadelphia.

Those inspections ended with 17 citation items: 11 serious and 6 other-than-serious.

Penalties were first proposed at $23,650 and now stand at $13,109, 45% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Roma Steel Erection Inc. averages $3,500 (1 cited inspection).

Roma Steel Erection Inc.: OSHA citation items per year, 1987 to 2023
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

274employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Roma Steel Erection Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346887433 OPENED AUG 3, 2023Closed

Planned · Complete · Safety · 3 employees at the site · Closed Mar 6, 2024

3200 Walnut Street, Philadelphia, PA 19104 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341069854 OPENED NOV 17, 2015Closed

Referral · Partial · Safety · 62 employees at the site · Closed Feb 19, 2016

1213 Walnut Street, Philadelphia, PA 19103 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Other-than-serious$3,500$3,500Nov 27, 2015Final

Inspection 339025959 OPENED APR 26, 2013Closed

Referral · Partial · Safety · 50 employees at the site · Closed Mar 18, 2014

315 Chestnut Street 24-30 S 3rd Street, Philadelphia, PA 19106 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(b)(1) · Fall protection
Other-than-serious$6,300$0Sep 30, 2013Final

Inspection 314236084 OPENED AUG 1, 2011Closed

Unprogrammed related · Partial · Safety · 50 employees at the site · Closed May 7, 2012

437 Chestnut Street, Philadelphia, PA 19106 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.351(b)(4) · Arc welding and cutting
Serious$4,500$3,375Jan 27, 2012Closed

Inspection 310721105 OPENED MAY 13, 2008Closed

Referral · Partial · Safety · 5 employees at the site · Closed Feb 25, 2009

4231 North Concourse Drive, Philadelphia, PA 19131 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.760(a)(1) · Fall protection
Serious$3,000$2,000Jul 17, 2008Final
Citation 1, item 2a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,000$2,000Jul 17, 2008Final
Citation 1, item 2b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0Jul 17, 2008Final
Citation 1, item 2c
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Jul 17, 2008Final

Inspection 305373391 OPENED DEC 18, 2002Closed

Unprogrammed related · Partial · Safety · 15 employees at the site · Closed Feb 27, 2003

Lincoln Financial Center, Philadelphia, PA 19148 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.351(b)(4) · Arc welding and cutting
Serious$900$585Feb 4, 2003Closed
Citation 1, item 1b
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Feb 4, 2003Closed

Inspection 303874879 OPENED MAY 8, 2001Closed

Referral · Partial · Safety · 16 employees at the site · Closed Mar 8, 2002

434 N. 15th Street, Philadelphia, PA 19103 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1b
29 CFR 1926.251(a)(1) · Rigging equipment for material handling
Serious$0$0Jun 25, 2001Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,500$900Jun 25, 2001Final

Inspection 303873582 OPENED FEB 8, 2001Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Mar 7, 2001

Byrne/ Green Buildings, Philadelphia, PA 19106 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.351(b)(4) · Arc welding and cutting
Serious$575$374Feb 26, 2001Closed
2 older inspections

Inspection 302625256 OPENED JUL 20, 1999Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Sep 28, 1999

Lincoln Financial Center, Philadelphia, PA 19148 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.352(d) · Fire prevention
Serious$375$375Jul 30, 1999Closed

Inspection 786392 OPENED APR 9, 1987Closed

Unprogrammed related · Complete · Safety · 2 employees at the site · Closed Oct 15, 1987

2 Logan Square, Philadelphia, PA 19103 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Jun 18, 1987Closed
Citation 1, item 2
29 CFR 1926.20(b)(1) · Construction safety programs
Other-than-serious$0$0Jun 18, 1987Closed
Citation 1, item 3
29 CFR 1926.50(d)(1) · Medical services and first aid
Other-than-serious$0$0Jun 18, 1987Closed
Citation 1, item 4
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Other-than-serious$0$0Jun 18, 1987Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.251 · Rigging equipment for material handling

29 CFR 1926.251(a)(1)

(a) General. (1) Rigging equipment for material handling shall be inspected prior to use on each shift and as necessary during its use to ensure that it is safe. Defective rigging equipment shall be removed from service.

29 CFR 1926.351 · Arc welding and cutting

29 CFR 1926.352 · Fire prevention

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.760 · Fall protection

Other structural steel and precast concrete contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.