OSHA SearchOSHA records by employer

Roman Vicente: OSHA inspections and violations

Mobile, Alabama · Masonry Contractors · NAICS 238140

1inspections
10citation items
$9,678current penalties
Feb 8, 2024last inspection

OSHA inspectors have visited Roman Vicente in Alabama one time.

It opened on Feb 8, 2024 as a planned inspection, in Mobile.

In all, OSHA issued 10 citation items: 10 serious.

The penalties, $9,678 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 8 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Roman Vicente averages $9,678 across 1 cited inspection.

Roman Vicente: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

100employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Roman Vicente and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347270985 OPENED FEB 8, 2024Closed

Planned · Partial · Safety · 4 employees at the site · Closed Oct 5, 2026

7525 Old Shell Rd., Mobile, AL 36608 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,839$4,839Feb 28, 2024Final
Citation 1, item 1b
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$0$0Feb 28, 2024Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 28, 2024Final
Citation 1, item 1d
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Feb 28, 2024Final
Citation 1, item 1e
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Feb 28, 2024Final
Citation 1, item 1f
29 CFR 1926.452(c)(3) · Rules for each type of scaffold
Serious$0$0Feb 28, 2024Final
Citation 1, item 2a
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Serious$4,839$4,839Feb 28, 2024Final
Citation 1, item 2b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Feb 28, 2024Final
Citation 1, item 2c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Feb 28, 2024Final
Citation 1, item 2d
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Feb 28, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.452 · Rules for each type of scaffold