OSHA SearchOSHA records by employer

Romo's Plastering: OSHA inspections and violations

San Antonio, Texas · Drywall and Insulation Contractors · NAICS 238310

2inspections
9citation items
$12,210current penalties
Jan 29, 2020last inspection

Since 2006, OSHA inspectors have visited Romo's Plastering in Texas 2 times.

The most recent inspection opened on Jan 29, 2020 as a planned inspection, in San Antonio.

In all, OSHA issued 9 citation items: 9 serious.

The penalties, $12,210 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Romo's Plastering averages $10,410 across 1 cited inspection.

Romo's Plastering: OSHA citation items per year, 2006 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Romo's Plastering and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344589734 OPENED JAN 29, 2020Closed

Planned · Partial · Safety · 10 employees at the site · Closed Sep 19, 2022

4835 Usaa Blvd, San Antonio, TX 78240 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,892$2,892Apr 8, 2020Final
Citation 1, item 2
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$2,313$2,313Apr 8, 2020Final
Citation 1, item 3
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,313$2,313Apr 8, 2020Final
Citation 1, item 4
29 CFR 1926.454(a) · Scaffold training
Serious$2,892$2,892Apr 8, 2020Final

Inspection 309754612 OPENED AUG 11, 2006Closed

Planned · Partial · Safety · 7 employees at the site · Closed Aug 13, 2009

4102 Naco Perrin Blvd, San Antonio, TX 78217 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$450$450Sep 28, 2006Closed
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$450$450Sep 28, 2006Closed
Citation 1, item 2b
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0Sep 28, 2006Closed
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$450$450Sep 28, 2006Closed
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$450$450Sep 28, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(c)(2)(i)

(i) Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

Other drywall and insulation contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.